| Assessment Year | 2003 |
|---|---|
| Principal Product | Wines |
| NAICS | 312130: Wineries |
| SIC | 2084: Wines, Brandy, and Brandy Spirits |
| Sales Range | $50 M to 100M |
| # of Employees | 53 |
| Plant Area |
100,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 5,137
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $140,507 | 1,338,640 |
kWh
|
$0.10 |
| Electricity Demand | $39,460 | 3,811 |
kW-mo/yr
|
$10.35 |
| Natural Gas | $10,134 | 1,676 |
MMBtu
|
$6.05 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $59,233 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $18,201 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7241: Install outside air damper / economizer on hvac unit | $2,671 | - |
$2,671
25,446
kWh
|
- | - | - | |
| 02 | 2.6218: Turn off equipment when not in use | $244 | - |
$244
2,329
kWh
|
- | - | - | |
| 03 | 2.7442: Keep doors and windows shut when not on use | $9,405 | $4,145 |
$9,405
89,566
kWh
|
- | - | - | |
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $14,226 | $9,485 |
$10,741
102,332
kWh
|
$3,485
-
kW-mo/yr
|
- | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,081 | $830 |
$879
8,374
kWh
|
$202
-
kW-mo/yr
|
- | - | |
| 06 | 2.7145: Install skylights | $3,975 | $10,800 |
$2,623
24,990
kWh
|
$1,352
-
kW-mo/yr
|
- | - | |
| 07 | 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings | $3,034 | - | - | - | - | $3,034 | |
| 08 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $9,418 | $9,500 | - | - |
$9,418
-
lb
|
- | |
| 09 | 4.212: Adopt in-house material generation | $15,179 | $80,393 | - | - | - | $15,179 | |
| TOTAL RECOMMENDED | $59,233 | $115,153 |
$26,563
253,037
kWh
|
$5,039
-
kW-mo/yr
|
$9,418
-
lb
|
$18,213 | ||
| TOTAL IMPLEMENTED | $18,201 | $20,285 |
$13,364
127,322
kWh
|
$4,837
-
kW-mo/yr
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs