Assessment Year 1990
Principal Product PIPE THREADS & COUPLINGS
NAICS
n/a
SIC 3498: Fabricated Pipe and Pipe Fittings
Sales Range $10
M
to 50
M
# of Employees 162
Plant Area
n/a
Annual Production 60,000
pieces
Production Hrs. Annual 5,500
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $314,254 6,426,143
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $32,130 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $18,370

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.1311: Replace electrically-operated equipment with fossil fuel equipment $8,500 $27,000 $21,000
498,242
kWh
$(-12,500.0)
-
MMBtu
02 2.3212: Optimize plant power factor $7,790 $21,500 $7,790
-
kWh
-
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,600 $500 $4,600
169,695
kWh
-
04 2.6212: Turn off equipment during breaks, reduce operating time $4,000 - $4,000
149,472
kWh
-
05 2.6232: Install set-back timers $3,860 - $3,860
143,611
kWh
-
06 2.6212: Turn off equipment during breaks, reduce operating time $1,800 $400 $1,800
67,409
kWh
-
07 2.4312: Improve lubrication practices $1,400 - $1,400
51,290
kWh
-
08 2.7142: Utilize higher efficiency lamps and/or ballasts $180 $170 $180
2,638
kWh
-
TOTAL RECOMMENDED $32,130 $49,570 $44,630
1,082,357
kWh
$(-12,500.0)
-
MMBtu
TOTAL IMPLEMENTED $18,370 $22,570 $18,370
389,214
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs