Search Recommendations
ITAC logo
Search Recommendations
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,175

matching recommendations
$
$
ARC 2+ Digits Required
NAICS 3+ Digits Required
SIC 2+ Digits Required
3+ Characters Required for Products
ID Description Yearly
Savings
Imp
Cost
SD0337 #01 Y:2003 Utilize higher efficiency lamps and/or ballasts $1,690 $3,091
NC0281 #07 Y:2003 Remove or close off unneeded compressed air lines $700 $400
NC0281 #06 Y:2003 Eliminate leaks in inert gas and compressed air lines/ valves $2,158 $1,060
NC0281 #05 Y:2003 Install outside air damper / economizer on hvac unit $3,258 $4,000
NC0281 #04 Y:2003 Install outside air damper / economizer on hvac unit $10,838 $6,000
NC0281 #03 Y:2003 Reduce the pressure of compressed air to the minimum required $7,625 $35,000
NC0281 #02 Y:2003 Use / purchase optimum sized compressor $73,723 $50
NC0281 #01 Y:2003 Install adequate dryers on air lines to eliminate blowdown $193,423 $70,000
WV0288 #14 Y:2003 Install compressor air intakes in coolest locations $95 $200
WV0288 #13 Y:2003 Chill water to the highest temperature possible $203 $25
WV0288 #12 Y:2003 Utilize energy-efficient belts and other improved mechanisms $804 $1,100
WV0288 #11 Y:2003 Use adjustable frequency drive or multiple speed motors on existing system $2,876 $3,500
WV0288 #10 Y:2003 Use / purchase optimum sized compressor $3,739 $575
WV0288 #09 Y:2003 Reduce the pressure of compressed air to the minimum required $3,932 $50
WV0288 #08 Y:2003 Utilize higher efficiency lamps and/or ballasts $4,040 $3,210
WV0288 #07 Y:2003 Develop a repair/replace policy $4,573 $1,000
WV0288 #06 Y:2003 Replace obsolete burners with more efficient ones $5,772 $27,600
WV0288 #05 Y:2003 Use waste heat from flue gases to heat space conditioning air $6,212 $1,200
WV0288 #04 Y:2003 Reduce illumination to minimum necessary levels $8,061 $250
WV0288 #03 Y:2003 Use or replace with energy efficient substitutes $9,120 $700