26
matching recommendations
$
$
ARC | 2+ Digits Required | |
NAICS | 3+ Digits Required | |
SIC | Power laundries, family and commercial | |
3+ Characters Required for Products |
ID | # | Year | Description | Yearly Savings |
Implementation
Imp Cost |
Status |
---|---|---|---|---|---|---|
DL0260 #09 Y:2025 | 09 | 2025 | Eliminate or reduce compressed air usage | $4,105 | - |
n/a
|
DL0260 #08 Y:2025 | 08 | 2025 | Eliminate leaks in inert gas and compressed air lines/ valves | $19,619 | $9,000 |
n/a
|
DL0260 #07 Y:2025 | 07 | 2025 | Remove or close off unneeded compressed air lines | $1,580 | - |
n/a
|
DL0260 #06 Y:2025 | 06 | 2025 | Use / purchase optimum sized compressor | $15,800 | $60,000 |
n/a
|
DL0260 #05 Y:2025 | 05 | 2025 | Minimize use of outside make-up air for ventilation except when used for economizer cycle | $4,400 | $20,000 |
n/a
|
DL0260 #04 Y:2025 | 04 | 2025 | Reduce combustion air flow to optimum | $1,763 | $5,000 |
n/a
|
DL0260 #03 Y:2025 | 03 | 2025 | Recover waste heat from equipment | $58,770 | $200,000 |
n/a
|
DL0260 #02 Y:2025 | 02 | 2025 | Increase amount of condensate returned | $4,398 | - |
n/a
|
DL0260 #01 Y:2025 | 01 | 2025 | Recover heat from exhausted steam, hot air or hot water | $30,961 | $16,000 |
n/a
|
IA0529 #06 Y:2014 | 06 | 2014 | Use steam condensate for hot water supply (non-potable) | $1,950 | $5,000 | |
IA0529 #05 Y:2014 | 05 | 2014 | Install spectral reflectors / delamp | $569 | $210 | |
IA0529 #04 Y:2014 | 04 | 2014 | Install / repair insulation on steam lines | $373 | $1,155 | |
IA0529 #03 Y:2014 | 03 | 2014 | Install vinyl strip / high speed / air curtain doors | $214 | $284 | |
IA0529 #02 Y:2014 | 02 | 2014 | Use most efficient type of electric motors | $2,154 | $7,444 | |
IA0529 #01 Y:2014 | 01 | 2014 | Utilize higher efficiency lamps and/or ballasts | $5,348 | $21,947 | |
DL0117 #05 Y:2013 | 05 | 2013 | Turn off equipment when not in use | $23,476 | $5,870 | |
DL0117 #04 Y:2013 | 04 | 2013 | Recover waste heat from equipment | $138,552 | $277,104 | |
DL0117 #03 Y:2013 | 03 | 2013 | Utilize higher efficiency lamps and/or ballasts | $6,400 | $6,000 | |
DL0117 #02 Y:2013 | 02 | 2013 | Eliminate leaks in inert gas and compressed air lines/ valves | $60,922 | $5,695 | |
DL0117 #01 Y:2013 | 01 | 2013 | Upgrade controls on compressors | $3,345 | $500 |