15,934

matching recommendations
$
$
ARC 2+ Digits Required
NAICS 3+ Digits Required
SIC Industrial and commercial machinery and computer equipment
3+ Characters Required for Products
ID Description Yearly
Savings
Imp
Cost
NL0142 #07 Y:2026 Eliminate leaks in inert gas and compressed air lines/ valves $232 $455
NL0142 #06 Y:2026 Close holes and openings in building such as broken windows $2,125 $1,561
NL0142 #05 Y:2026 Apply for tax-free status for energy purchases $3,170 $400
NL0142 #04 Y:2026 Turn off equipment during breaks, reduce operating time $3,653 $50
NL0142 #03 Y:2026 Utilize higher efficiency lamps and/or ballasts $4,076 $8,547
NL0142 #02 Y:2026 Utilize sensors controlling roof and wall openings $5,500 $8,965
NL0142 #01 Y:2026 Install occupancy sensors $18,097 $18,462
NL0141 #06 Y:2026 Insulate bare equipment $42 $109
NL0141 #05 Y:2026 Install compressor air intakes in coolest locations $269 $783
NL0141 #04 Y:2026 Install occupancy sensors $369 $488
NL0141 #03 Y:2026 Utilize higher efficiency lamps and/or ballasts $316 $740
NL0141 #02 Y:2026 Eliminate leaks in inert gas and compressed air lines/ valves $2,001 $562
NL0141 #01 Y:2026 Install vinyl strip / high speed / air curtain doors $4,281 $652
SU0608 #10 Y:2026 Install compressor air intakes in coolest locations $80 $352
SU0608 #09 Y:2026 Conserve energy by efficient use of vending machines $429 $1,559
SU0608 #08 Y:2026 Use or replace with energy efficient substitutes $538 $1,009
SU0608 #07 Y:2026 Eliminate leaks in inert gas and compressed air lines/ valves $584 $122
SU0608 #06 Y:2026 Reduce space conditioning during non-working hours $190 -
SU0608 #05 Y:2026 Reduce the pressure of compressed air to the minimum required $194 -
SU0608 #04 Y:2026 Eliminate/reduce an operation $2,913 -