Search Recommendations
ITAC logo
Search Recommendations
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

21,541

matching recommendations
$
$
ARC 2+ Digits Required
NAICS 3+ Digits Required
SIC Fabricated metal products, except machinery and transportation equipment
3+ Characters Required for Products
ID Description Yearly
Savings
Imp
Cost
WM0264 #07 Y:2026 Install occupancy sensors $1,609 $404
WM0264 #06 Y:2026 Utilize higher efficiency lamps and/or ballasts $3,214 $4,160
WM0264 #05 Y:2026 Install compressor air intakes in coolest locations $3,231 $830
WM0264 #04 Y:2026 Use waste heat from hot flue gases to preheat $4,638 $68,500
WM0264 #03 Y:2026 Reduce space conditioning during non-working hours $8,670 $3,600
WM0264 #02 Y:2026 Reduce the pressure of compressed air to the minimum required $21,881 -
WM0264 #01 Y:2026 Eliminate leaks in inert gas and compressed air lines/ valves $27,876 $17,100
LE0619 #08 Y:2026 Eliminate leaks in inert gas and compressed air lines/ valves $3,777 $18,000
LE0619 #07 Y:2026 Replace existing hvac unit with high efficiency model $13,065 $57,445
LE0619 #06 Y:2026 Use cooling tower or economizer to replace chiller cooling $2,180 $6,564
LE0619 #05 Y:2026 Use adjustable frequency drive or multiple speed motors on existing system $1,009 $2,000
LE0619 #04 Y:2026 Re-use or recycle hot or cold process exhaust air $2,218 $4,000
LE0619 #03 Y:2026 Install back-up equipment $28,409 $40,000
LE0619 #02 Y:2026 Eliminate leaks in inert gas and compressed air lines/ valves $1,171 $1,000
LE0619 #01 Y:2026 Utilize higher efficiency lamps and/or ballasts $1,477 $1,318
OK1175 #05 Y:2026 Conserve energy by efficient use of vending machines $168 $248
OK1175 #04 Y:2026 Clean and maintain refrigerant condensers and towers $530 $964
OK1175 #03 Y:2026 Use computer programs to optimize hvac performance $3,749 $19,250
OK1175 #02 Y:2026 Eliminate leaks in inert gas and compressed air lines/ valves $1,605 $277
OK1175 #01 Y:2026 Use solar heat to make electricty $9,655 $117,936