68
matching recommendations
$
$
| ARC | 2+ Digits Required | |
| NAICS | 3+ Digits Required | |
| SIC | Alkalies and chlorine | |
| 3+ Characters Required for Products | ||
| ID | # | Year | Description | Yearly Savings |
Implementation
Imp Cost |
Status |
|---|---|---|---|---|---|---|
| WV0599 #14 Y:2020 | 14 | 2020 | Insulate bare equipment | $361 | $1,123 | |
| WV0599 #13 Y:2020 | 13 | 2020 | Eliminate leaks in inert gas and compressed air lines/ valves | $1,644 | $1,250 | |
| WV0599 #12 Y:2020 | 12 | 2020 | Utilize energy-efficient belts and other improved mechanisms | $3,517 | $2,256 | |
| WV0599 #11 Y:2020 | 11 | 2020 | Recover heat from exhausted steam, hot air or hot water | $4,587 | $27,500 | |
| WV0599 #10 Y:2020 | 10 | 2020 | Recover waste heat from equipment | $7,356 | $21,400 | |
| WV0599 #09 Y:2020 | 09 | 2020 | Improve combustion control capability | $9,278 | $8,650 | |
| WV0599 #08 Y:2020 | 08 | 2020 | Replace obsolete burners with more efficient ones | $10,828 | $39,480 | |
| WV0599 #07 Y:2020 | 07 | 2020 | Use adjustable frequency drive or multiple speed motors on existing system | $12,054 | $14,700 | |
| WV0599 #06 Y:2020 | 06 | 2020 | Develop a repair/replace policy | $13,389 | $2,433 | |
| WV0599 #05 Y:2020 | 05 | 2020 | Analyze flue gas for proper air/fuel ratio | $15,981 | $2,000 | |
| WV0599 #04 Y:2020 | 04 | 2020 | Use waste heat from hot flue gases to preheat | $18,379 | $45,860 | |
| WV0599 #03 Y:2020 | 03 | 2020 | Install outside air damper / economizer on hvac unit | $25,793 | $83,200 | |
| WV0599 #02 Y:2020 | 02 | 2020 | Utilize higher efficiency lamps and/or ballasts | $50,634 | $94,500 | |
| WV0599 #01 Y:2020 | 01 | 2020 | Use steam condensate for hot water supply (non-potable) | $126,151 | $250,000 | |
| SU0449 #05 Y:2017 | 05 | 2017 | Use waste heat from hot flue gases to preheat | $3,182 | $15,784 | |
| SU0449 #04 Y:2017 | 04 | 2017 | Utilize higher efficiency lamps and/or ballasts | $1,895 | $3,697 | |
| SU0449 #03 Y:2017 | 03 | 2017 | Utilize higher efficiency lamps and/or ballasts | $194 | $208 | |
| SU0449 #02 Y:2017 | 02 | 2017 | Eliminate/reduce an operation | $1,271 | $900 | |
| SU0449 #01 Y:2017 | 01 | 2017 | Install / repair insulation on steam lines | $2,375 | $267 | |
| UM0471 #05 Y:2016 | 05 | 2016 | Use waste heat from hot flue gases to preheat | $1,664 | $3,435 |
n/a
|