1,250
matching recommendations| ID | # | Year | Description | Yearly Savings |
Implementation
Imp Cost |
Status |
|---|---|---|---|---|---|---|
| UD0755 #11 Y:2006 | 11 | 2006 | Upgrade controls on compressors | $2,520 | - | |
| UD0755 #10 Y:2006 | 10 | 2006 | Use optimum thickness insulation | $4,545 | $16,005 | |
| UD0755 #09 Y:2006 | 09 | 2006 | Recover waste heat from equipment | $11,340 | $2,000 | |
| UD0755 #08 Y:2006 | 08 | 2006 | Use power during off-peak periods | $12,404 | - | |
| UD0755 #07 Y:2006 | 07 | 2006 | Upgrade controls on compressors | $12,600 | $15,000 | |
| UD0755 #06 Y:2006 | 06 | 2006 | Utilize higher efficiency lamps and/or ballasts | $14,952 | $19,500 | |
| UD0755 #05 Y:2006 | 05 | 2006 | Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $33,617 | $337,437 | |
| UD0755 #04 Y:2006 | 04 | 2006 | Replace electric motors with back pressure steam turbines and use exhaust steam for process heat | $46,585 | $42,000 | |
| UD0755 #03 Y:2006 | 03 | 2006 | Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $49,140 | $253,091 | |
| UD0755 #02 Y:2006 | 02 | 2006 | Utilize higher efficiency lamps and/or ballasts | $57,728 | $10,396 | |
| UD0755 #01 Y:2006 | 01 | 2006 | Enhance sensitivity of temperature control and cutoff | $73,500 | $147,000 | |
| GT0833 #08 Y:2006 | 08 | 2006 | Eliminate or reduce compressed air usage | $36,891 | $62,250 | |
| GT0833 #07 Y:2006 | 07 | 2006 | Pay bills on time to avoid late fees | $6,204 | - | |
| GT0833 #06 Y:2006 | 06 | 2006 | Eliminate leaks in inert gas and compressed air lines/ valves | $1,653 | $550 | |
| GT0833 #05 Y:2006 | 05 | 2006 | Separate and recycle scrap metal to foundry or for sale | $29,400 | - | |
| GT0833 #04 Y:2006 | 04 | 2006 | Use / purchase optimum sized compressor | $9,806 | $18,000 | |
| GT0833 #03 Y:2006 | 03 | 2006 | Utilize higher efficiency lamps and/or ballasts | $9,153 | - | |
| GT0833 #02 Y:2006 | 02 | 2006 | Eliminate/reduce an operation | $137,445 | - | |
| GT0833 #01 Y:2006 | 01 | 2006 | Turn off equipment during breaks, reduce operating time | $870,069 | $100,000 | |
| UF0392 #07 Y:2006 | 07 | 2006 | Use optimum thickness insulation | $2,922 | $1,680 |