Search Recommendations
ITAC logo
Search Recommendations
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,471

matching recommendations
$
$
ARC 2+ Digits Required
NAICS Paperboard container manufacturing
SIC 2+ Digits Required
3+ Characters Required for Products
ID Description Yearly
Savings
Imp
Cost
CM1051 #12 Y:2025 Apply for tax-free status for energy purchases $12,476 $8,000
CM1051 #11 Y:2025 Utilize higher efficiency lamps and/or ballasts $13,510 $63,288
CM1051 #10 Y:2025 Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses $387 $8,216
CM1051 #09 Y:2025 Install partitions to reduce size of conditioned space $402 $3,500
CM1051 #08 Y:2025 Eliminate or reduce compressed air usage $1,212 $1,051
CM1051 #07 Y:2025 Use most efficient type of electric motors $383 $2,812
CM1051 #06 Y:2025 Use proper thickness of insulation on building envelope $14,825 $19,854
CM1051 #05 Y:2025 Turn off equipment when not in use $494 -
CM1051 #04 Y:2025 Eliminate leaks in inert gas and compressed air lines/ valves $2,913 $679
CM1051 #03 Y:2025 Increase efficiency of trucks $41,631 $160,456
CM1051 #02 Y:2025 Utilize higher efficiency lamps and/or ballasts $16,537 $68,962
CM1051 #01 Y:2025 Use solar heat to make electricty $73,410 $659,381
NL0110 #05 Y:2025 Utilize energy-efficient belts and other improved mechanisms $527 $700
NL0110 #04 Y:2025 Meter waste water $4,494 $2,400
NL0110 #03 Y:2025 Eliminate leaks in inert gas and compressed air lines/ valves $5,063 $4,500
NL0110 #02 Y:2025 Reschedule plant operations or reduce load to avoid peaks $7,360 $160
NL0110 #01 Y:2025 Use solar heat to make electricty $262,812 $4,671,994
SD0663 #11 Y:2024 Replace existing hvac unit with high efficiency model $10,593 $35,000
SD0663 #10 Y:2024 Install compressor air intakes in coolest locations $6,427 $3,278
SD0663 #09 Y:2024 Eliminate or reduce compressed air usage $3,465 $3,200