| Assessment Year | 2026 |
|---|---|
| Principal Product | Paperboard Folding Cartons |
| NAICS | 322212: Folding Paperboard Box Manufacturing |
| SIC | 2657: Folding Paperboard Boxes, Including Sanitary |
| Sales Range | $100 M to 500M |
| # of Employees | 320 |
| Plant Area |
440,300
ft2
|
| Annual Production | 58,943
ton
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,034,083 | 9,764,326 |
kWh
|
$0.11 |
| Natural Gas | $136,307 | 19,200 |
MMBtu
|
$7.10 |
| TOTAL YEARLY COSTS | $1,170,390 | |||
| RECOMMENDED SAVINGS* | $779,269 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $9,373 | $100 |
$9,373
88,420
kWh
|
- | - | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $86,480 | $1,850 |
$89,380
843,207
kWh
|
- | $(-2,900.0) | |
| 03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $19,620 | $20,000 |
$19,620
185,092
kWh
|
- | - | |
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $7,194 | $9,500 |
$7,194
67,872
kWh
|
- | - | |
| 05 | 2.4239: Eliminate or reduce compressed air usage | $10,234 | $14,450 |
$10,234
96,556
kWh
|
- | - | |
| 06 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,511 | $2,210 |
$1,511
14,250
kWh
|
- | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,900 | $14,637 |
$8,900
83,966
kWh
|
- | - | |
| 08 | 2.7135: Install occupancy sensors | $4,069 | $9,210 |
$4,069
38,385
kWh
|
- | - | |
| 09 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $282,619 | $966,000 |
$371,424
3,504,000
kWh
|
$(-88,805.0)
-
MMBtu
|
- | |
| 10 | 2.9114: Use solar heat to make electricty | $349,269 | $2,074,730 |
$349,269
3,296,380
kWh
|
- | - | |
| TOTAL RECOMMENDED | $779,269 | $3,112,687 |
$870,974
8,218,128
kWh
|
$(-88,805.0)
-
MMBtu
|
$(-2,900.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs