ITAC Assessment: GT1012
ITAC logo
ITAC Assessment: GT1012
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2026
Principal Product Paperboard Folding Cartons
NAICS 322212: Folding Paperboard Box Manufacturing
SIC 2657: Folding Paperboard Boxes, Including Sanitary
Sales Range $100
M
to 500
M
# of Employees 320
Plant Area 440,300
ft2
Annual Production 58,943
ton
Production Hrs. Annual 8,760
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,034,083 9,764,326
kWh
Natural Gas $136,307 19,200
MMBtu
TOTAL YEARLY COSTS $1,170,390
RECOMMENDED SAVINGS* $779,269 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Personnel Changes Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $9,373 $100 $9,373
88,420
kWh
- -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $86,480 $1,850 $89,380
843,207
kWh
- $(-2,900.0)
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $19,620 $20,000 $19,620
185,092
kWh
- -
04 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $7,194 $9,500 $7,194
67,872
kWh
- -
05 2.4239: Eliminate or reduce compressed air usage $10,234 $14,450 $10,234
96,556
kWh
- -
06 2.6212: Turn off equipment during breaks, reduce operating time $1,511 $2,210 $1,511
14,250
kWh
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $8,900 $14,637 $8,900
83,966
kWh
- -
08 2.7135: Install occupancy sensors $4,069 $9,210 $4,069
38,385
kWh
- -
09 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat $282,619 $966,000 $371,424
3,504,000
kWh
$(-88,805.0)
-
MMBtu
-
10 2.9114: Use solar heat to make electricty $349,269 $2,074,730 $349,269
3,296,380
kWh
- -
TOTAL RECOMMENDED $779,269 $3,112,687 $870,974
8,218,128
kWh
$(-88,805.0)
-
MMBtu
$(-2,900.0)
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs