| Assessment Year | 2024 |
|---|---|
| Principal Product | Lumber |
| NAICS | 321113: Sawmills |
| SIC | 2421: Sawmills and Planing Mills, General |
| Sales Range | $10 M to 50M |
| # of Employees | 35 |
| Plant Area |
57,111
ft2
|
| Annual Production | 12,000
thousand feet
|
| Production Hrs. Annual | 2,600
hrs
|
| Location (State) | West Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $209,616 | 2,288,505 |
kWh
|
$0.092 |
| Electricity Demand | $99,295 | 9,412 |
kW-mo/yr
|
$10.55 |
| Electricity Fees | $5,800 | - |
|
- |
| Other Gas | $465,535 | 20,544 |
MMBtu
|
$22.66 |
| TOTAL YEARLY COSTS | $780,246 | |||
| RECOMMENDED SAVINGS* | $88,039 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $22,356 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Gas Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.1224: Replace boiler | $38,907 | $149,240 | - | - |
$38,907
-
MMBtu
|
- | |
| 02 | 2.4322: Use or replace with energy efficient substitutes | $21,406 | $98,076 |
$13,979
152,612
kWh
|
$7,427
-
kW-mo/yr
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,019 | $3,647 |
$5,886
64,255
kWh
|
$3,133
-
kW-mo/yr
|
- | - | |
| 04 | 2.2425: Use flue gases to heat process or service water | $5,370 | $18,750 | - | - |
$5,370
-
MMBtu
|
- | |
| 05 | 2.4157: Establish a predictive maintenance program | $4,482 | $1,500 |
$3,469
37,866
kWh
|
$1,846
-
kW-mo/yr
|
- | $(-833.0) | |
| 06 | 2.2511: Insulate bare equipment | $2,493 | $1,302 | - | - |
$2,493
-
MMBtu
|
- | |
| 07 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,266 | $1,107 | - | - |
$2,266
-
MMBtu
|
- | |
| 08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,181 | $1,063 |
$1,421
15,517
kWh
|
$760
-
kW-mo/yr
|
- | - | |
| 09 | 2.4151: Develop a repair/replace policy | $1,429 | $6,850 |
$1,322
14,432
kWh
|
$707
-
kW-mo/yr
|
- | $(-600.0) | |
| 10 | 2.4239: Eliminate or reduce compressed air usage | $486 | $242 |
$317
3,459
kWh
|
$169
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $88,039 | $281,777 |
$26,394
288,141
kWh
|
$14,042
-
kW-mo/yr
|
$49,036
-
MMBtu
|
$(-1,433.0) | ||
| TOTAL IMPLEMENTED | $22,356 | $15,711 |
$12,415
135,529
kWh
|
$6,615
-
kW-mo/yr
|
$4,759
-
MMBtu
|
$(-1,433.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Gas Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs