Assessment Year | 2023 |
---|---|
Principal Product | Plastic Products |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
1,000,000
ft2
|
Annual Production | 6,000
ton
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | West Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,406,818 | 34,830,934 |
kWh
|
$0.069 |
TOTAL YEARLY COSTS | $2,406,818 | |||
RECOMMENDED SAVINGS* | $309,831 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $65,058 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $193,156 | $160,000 |
$193,156
2,795,316
kWh
|
- | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $42,958 | $210,200 |
$42,958
621,672
kWh
|
- | |
03 | 2.4157: Establish a predictive maintenance program | $22,798 | $1,500 |
$24,781
358,626
kWh
|
$(-1,983.0) | |
04 | 2.4157: Establish a predictive maintenance program | $13,975 | $1,500 |
$16,458
238,177
kWh
|
$(-2,483.0) | |
05 | 2.4151: Develop a repair/replace policy | $13,792 | $1,942 |
$13,942
201,772
kWh
|
$(-150.0) | |
06 | 2.4224: Upgrade controls on compressors | $8,659 | $22,700 |
$8,659
125,323
kWh
|
- | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $6,902 | $2,750 |
$6,902
99,885
kWh
|
- | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,967 | $2,160 |
$4,967
71,885
kWh
|
- | |
09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,118 | $7,210 |
$2,118
30,652
kWh
|
- | |
10 | 2.2511: Insulate bare equipment | $506 | $166 |
$506
7,325
kWh
|
- | |
TOTAL RECOMMENDED | $309,831 | $410,128 |
$314,447
4,550,633
kWh
|
$(-4,616.0) | ||
TOTAL IMPLEMENTED | $65,058 | $17,228 |
$69,674
1,008,322
kWh
|
$(-4,616.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs