Assessment Year | 2012 |
---|---|
Principal Product | snow and ice removal equipment |
NAICS | 333112: Lawn and Garden Tractor and Home Lawn and Garden Equipment Manufacturing |
SIC | 3524: Lawn and Garden Tractors and Home Lawn and Garden Equipment |
Sales Range | $10 M to 50M |
# of Employees | 47 |
Plant Area |
250,000
ft2
|
Annual Production | 25,000
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $350,719 | 4,057,649 |
kWh
|
$0.086 |
Electricity Demand | $82,583 | 12,402 |
kW-mo/yr
|
$6.66 |
Electricity Fees | $3,031 | - |
|
- |
Natural Gas | $121,875 | 19,042 |
MMBtu
|
$6.40 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $43,394 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,791 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $20,085 | $108,401 |
$13,731
158,929
kWh
|
$6,354
-
kW-mo/yr
|
- | - | |
02 | 2.2414: Use waste heat from hot flue gases to preheat | $5,088 | $7,920 | - | - |
$5,088
-
MMBtu
|
- | |
03 | 2.1221: Replace obsolete burners with more efficient ones | $4,992 | $13,611 | - | - |
$4,992
-
MMBtu
|
- | |
04 | 2.7231: Use radiant heater for spot heating | $3,789 | $19,607 | - | - |
$3,789
-
MMBtu
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,331 | $11,667 |
$1,592
18,426
kWh
|
$739
-
kW-mo/yr
|
- | - | |
06 | 2.4151: Develop a repair/replace policy | $1,836 | $775 |
$1,421
16,449
kWh
|
$659
-
kW-mo/yr
|
- | $(-244.0) | |
07 | 2.1135: Repair furnaces and oven doors so that they seal efficiently | $1,686 | $2,767 |
$(-375.0)
(-4,340)
kWh
|
$(-173.0)
-
kW-mo/yr
|
$2,234
-
MMBtu
|
- | |
08 | 2.4239: Eliminate or reduce compressed air usage | $1,449 | $468 |
$991
11,469
kWh
|
$458
-
kW-mo/yr
|
- | - | |
09 | 2.4239: Eliminate or reduce compressed air usage | $1,183 | $2,711 |
$810
9,370
kWh
|
$373
-
kW-mo/yr
|
- | - | |
10 | 2.4157: Establish a predictive maintenance program | $531 | $1,000 |
$625
7,237
kWh
|
$286
-
kW-mo/yr
|
- | $(-380.0) | |
11 | 2.4231: Reduce the pressure of compressed air to the minimum required | $424 | $50 |
$290
3,359
kWh
|
$134
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $43,394 | $168,977 |
$19,085
220,899
kWh
|
$8,830
-
kW-mo/yr
|
$16,103
-
MMBtu
|
$(-624.0) | ||
TOTAL IMPLEMENTED | $2,791 | $1,825 |
$2,336
27,045
kWh
|
$1,079
-
kW-mo/yr
|
- | $(-624.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs