ITAC Assessment: OK0147
ITAC logo
ITAC Assessment: OK0147
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1984
Principal Product ELECTRICAL CONNECTORS
NAICS
n/a
SIC 3678: Electronic Connectors
Sales Range $10
M
to 50
M
# of Employees 135
Plant Area
n/a
Annual Production 0
units
Production Hrs. Annual 4,160
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $154,192 3,461,020
kWh
Natural Gas $45,930 12,667
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $32,740 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $25,566

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,160 $900 $4,160
110,199
kWh
-
02 2.4239: Eliminate or reduce compressed air usage $509 $131 $509
13,482
kWh
-
03 2.1233: Analyze flue gas for proper air/fuel ratio $2,650 $6,252 - $2,650
-
MMBtu
04 2.2447: Heat water with exhaust heat $7,174 $6,955 $2,640
51,290
kWh
$4,534
-
MMBtu
05 2.3191: Use demand controller or load shedder $6,120 $1,236 $6,120
-
kWh
-
06 2.2122: Install / repair insulation on condensate lines $566 $333 - $566
-
MMBtu
07 2.1131: Repair faulty insulation in furnaces, boilers, etc $2,671 $1,647 - $2,671
-
MMBtu
08 2.1131: Repair faulty insulation in furnaces, boilers, etc $2,036 $720 $2,036
53,927
kWh
-
09 2.7261: Install timers and/or thermostats $492 $291 - $492
-
MMBtu
10 2.6218: Turn off equipment when not in use $6,362 $1,090 $6,362
168,523
kWh
-
TOTAL RECOMMENDED $32,740 $19,555 $21,827
397,421
kWh
$10,913
-
MMBtu
TOTAL IMPLEMENTED $25,566 $12,600 $19,187
346,131
kWh
$6,379
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs