Assessment Year | 2011 |
---|---|
Principal Product | glass and vinyl windows |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 72 |
Plant Area |
90,000
ft2
|
Annual Production | 52,000
pieces
|
Production Hrs. Annual | 2,184
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $83,225 | 927,878 |
kWh
|
$0.090 |
Natural Gas | $40,874 | 4,215 |
MMBtu
|
$9.70 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $27,330 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,637 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $11,820 | $1,000 | - |
$11,883
-
MMBtu
|
$(-63.0) | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,303 | $29,900 |
$4,303
47,975
kWh
|
- | - | |
03 | 2.7226: Use computer programs to optimize hvac performance | $2,561 | $4,294 | - |
$2,561
-
MMBtu
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,594 | $458 |
$1,594
17,775
kWh
|
- | - | |
05 | 2.2443: Re-use or recycle hot or cold process exhaust air | $1,328 | $10,400 |
$(-233.0)
(-2,661)
kWh
|
$2,561
-
MMBtu
|
$(-1,000.0) | |
06 | 2.2437: Recover waste heat from equipment | $1,319 | $268 | - |
$1,319
-
MMBtu
|
- | |
07 | 2.4221: Install compressor air intakes in coolest locations | $1,208 | $905 |
$1,208
13,471
kWh
|
- | - | |
08 | 2.4235: Remove or close off unneeded compressed air lines | $1,197 | - |
$1,197
13,343
kWh
|
- | - | |
09 | 2.4239: Eliminate or reduce compressed air usage | $739 | $785 |
$739
8,424
kWh
|
- | - | |
10 | 2.4231: Reduce the pressure of compressed air to the minimum required | $723 | $21 |
$723
8,057
kWh
|
- | - | |
11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $538 | $1,956 |
$538
5,996
kWh
|
- | - | |
TOTAL RECOMMENDED | $27,330 | $49,987 |
$10,069
112,380
kWh
|
$18,324
-
MMBtu
|
$(-1,063.0) | ||
TOTAL IMPLEMENTED | $19,637 | $31,379 |
$7,817
87,150
kWh
|
$11,883
-
MMBtu
|
$(-63.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs