Assessment Year 2007
Principal Product graphite tubes and rods, graphitized powder, ceramic components/parts an
NAICS 335991: Carbon and Graphite Product Manufacturing
SIC 3624: Carbon and Graphite Products
Sales Range $5
M
to 10
M
# of Employees 51
Plant Area 56,000
ft2
Annual Production 1,000,000
lb
Production Hrs. Annual 8,760
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $89,475 7,662,036
kWh
Electricity Demand $114,407 15,777
kW-mo/yr
Electricity Fees $9,170 -
Natural Gas $443,955 51,144
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $193,585 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $55,709

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings
01 2.2414: Use waste heat from hot flue gases to preheat $115,865 $26,750 - - $116,060
-
MMBtu
$(-195.0)
02 2.2511: Insulate bare equipment $42,691 $13,780 $3,013
257,547
kWh
$3,925
-
kW-mo/yr
$35,753
-
MMBtu
-
03 2.2426: Use waste heat from flue gases to heat space conditioning air $13,999 $13,900 $(-82.0)
(-7,032)
kWh
$(-111.0)
-
kW-mo/yr
$14,192
-
MMBtu
-
04 2.1233: Analyze flue gas for proper air/fuel ratio $10,204 $2,000 - - $10,399
-
MMBtu
$(-195.0)
05 2.2414: Use waste heat from hot flue gases to preheat $8,012 $15,100 - - $8,012
-
MMBtu
-
06 2.7134: Use photocell controls $1,311 $430 $566
48,355
kWh
$745
-
kW-mo/yr
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $846 - $367
31,339
kWh
$479
-
kW-mo/yr
- -
08 2.4157: Establish a predictive maintenance program $657 $276 $342
29,229
kWh
$445
-
kW-mo/yr
- $(-130.0)
TOTAL RECOMMENDED $193,585 $72,236 $4,206
359,438
kWh
$5,483
-
kW-mo/yr
$184,416
-
MMBtu
$(-520.0)
TOTAL IMPLEMENTED $55,709 $16,486 $4,288
366,470
kWh
$5,594
-
kW-mo/yr
$46,152
-
MMBtu
$(-325.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs