Assessment Year | 2005 |
---|---|
Principal Product | Kiln Dried Hardwood Lumber and Hardwood Flooring |
NAICS | 321113: Sawmills |
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
175,000
ft2
|
Annual Production | 23,000
thousand feet
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $379,494 | 10,211,753 |
kWh
|
$0.037 |
Electricity Demand | $236,050 | 24,297 |
kW-mo/yr
|
$9.72 |
Electricity Fees | $19,624 | - |
|
- |
Wood | $83,025 | 95,313 |
MMBtu
|
$0.87 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $178,488 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $39,295 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Wood Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3414: Burn waste to produce steam to drive a steam turbine generator set and use steam exhaust for heat | $137,755 | $1,055,656 |
$150,879
3,877,855
kWh
|
$57,446
-
kW-mo/yr
|
$(-70,570.0)
-
MMBtu
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $12,082 | $5,425 |
$6,874
176,679
kWh
|
$5,208
-
kW-mo/yr
|
- | - | |
03 | 2.4151: Develop a repair/replace policy | $8,791 | $869 |
$5,714
146,793
kWh
|
$4,577
-
kW-mo/yr
|
- | $(-1,500.0) | |
04 | 2.6212: Turn off equipment during breaks, reduce operating time | $6,268 | $25 |
$4,663
119,837
kWh
|
$1,605
-
kW-mo/yr
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,074 | $5,296 |
$2,367
55,841
kWh
|
$1,707
-
kW-mo/yr
|
- | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,839 | $50 |
$1,778
45,806
kWh
|
$1,061
-
kW-mo/yr
|
- | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,113 | - |
$1,043
26,815
kWh
|
$1,070
-
kW-mo/yr
|
- | - | |
08 | 2.2113: Repair or replace steam traps | $1,475 | $1,000 | - | - |
$1,925
-
MMBtu
|
$(-450.0) | |
09 | 2.2511: Insulate bare equipment | $1,173 | $885 | - | - |
$1,173
-
MMBtu
|
- | |
10 | 2.4221: Install compressor air intakes in coolest locations | $905 | $980 |
$577
14,824
kWh
|
$328
-
kW-mo/yr
|
- | - | |
11 | 2.7135: Install occupancy sensors | $533 | $2,113 |
$341
8,291
kWh
|
$192
-
kW-mo/yr
|
- | - | |
12 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $480 | $158 |
$279
7,159
kWh
|
$201
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $178,488 | $1,072,457 |
$174,515
4,479,900
kWh
|
$73,395
-
kW-mo/yr
|
$(-67,472.0)
-
MMBtu
|
$(-1,950.0) | ||
TOTAL IMPLEMENTED | $39,295 | $13,708 |
$22,718
578,930
kWh
|
$15,429
-
kW-mo/yr
|
$3,098
-
MMBtu
|
$(-1,950.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Wood Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs