Assessment Year | 2004 |
---|---|
Principal Product | Metal Stampings |
NAICS | 332119: Metal Crown, Closure, and Other Metal Stamping (except Automotive) |
SIC | 3469: Metal Stampings, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 34 |
Plant Area |
70,000
ft2
|
Annual Production | 3,500
ton
|
Production Hrs. Annual | 4,368
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $45,638 | 1,346,356 |
kWh
|
$0.034 |
Electricity Demand | $54,288 | 4,427 |
kW-mo/yr
|
$12.26 |
Electricity Fees | $1,813 | - |
|
- |
Natural Gas | $25,687 | 2,561 |
MMBtu
|
$10.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $62,491 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $57,328 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,584 | $3,731 |
$2,344
66,486
kWh
|
$2,240
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.3191: Use demand controller or load shedder | $3,141 | - | - |
$8,141
-
kW-mo/yr
|
$(-5,000.0) | - | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,134 | $292 |
$1,601
45,489
kWh
|
$1,533
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,072 | $7,735 |
$1,356
38,454
kWh
|
$1,716
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $3,067 | $7,050 |
$2,025
57,428
kWh
|
$1,042
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,066 | $2,200 |
$1,570
44,536
kWh
|
$1,496
-
kW-mo/yr
|
- | - | - | - | |
07 | 2.4322: Use or replace with energy efficient substitutes | $2,889 | $80 |
$1,477
41,933
kWh
|
$1,412
-
kW-mo/yr
|
- | - | - | - | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,260 | $50 |
$1,157
32,732
kWh
|
$1,103
-
kW-mo/yr
|
- | - | - | - | |
09 | 2.7492: Use proper thickness of insulation on building envelope | $2,096 | $1,967 | - | - | - |
$2,096
-
MMBtu
|
- | - | |
10 | 2.7135: Install occupancy sensors | $921 | $1,400 |
$471
13,349
kWh
|
$450
-
kW-mo/yr
|
- | - | - | - | |
11 | 2.4151: Develop a repair/replace policy | $731 | $300 |
$375
10,548
kWh
|
$356
-
kW-mo/yr
|
- | - | - | - | |
12 | 3.5316: Contract a wood pallet recycling company | $28,080 | $100 | - | - | - | - |
$28,080
-
lb
|
- | |
13 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $5,450 | $5,000 | - | - | - | - | - | $5,450 | |
TOTAL RECOMMENDED | $62,491 | $29,905 |
$12,376
350,955
kWh
|
$19,489
-
kW-mo/yr
|
$(-5,000.0) |
$2,096
-
MMBtu
|
$28,080
-
lb
|
$5,450 | ||
TOTAL IMPLEMENTED | $57,328 | $20,888 |
$10,351
293,527
kWh
|
$18,447
-
kW-mo/yr
|
$(-5,000.0) | - |
$28,080
-
lb
|
$5,450 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs