Assessment Year | 2004 |
---|---|
Principal Product | Printed Periodicals |
NAICS | 323111: Commercial Printing (except Screen and Books) |
SIC | 2759: Commercial Printing, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 175 |
Plant Area |
70,000
ft2
|
Annual Production | 0
lb
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $105,951 | 4,679,280 |
kWh
|
$0.023 |
Electricity Demand | $145,368 | 14,102 |
kW-mo/yr
|
$10.31 |
Natural Gas | $115,636 | 11,560 |
MMBtu
|
$10.00 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $55,914 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $32,493 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.1133: Adjust burners for efficient operation | $11,512 | $250 |
$8,188
361,808
kWh
|
$3,324
-
kW-mo/yr
|
- | - | |
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $9,827 | $5,000 | - |
$9,827
-
kW-mo/yr
|
- | - | |
03 | 2.2625: Chill water to the highest temperature possible | $6,964 | $86 |
$4,953
219,019
kWh
|
$2,011
-
kW-mo/yr
|
- | - | |
04 | 2.2628: Utilize a less expensive cooling method | $4,877 | $100,430 |
$2,692
118,964
kWh
|
$2,185
-
kW-mo/yr
|
- | - | |
05 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $4,643 | $1,290 |
$4,039
178,144
kWh
|
$1,636
-
kW-mo/yr
|
- | $(-1,032.0) | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,222 | $6,500 |
$1,591
70,320
kWh
|
$2,631
-
kW-mo/yr
|
- | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,923 | $86 |
$2,791
123,228
kWh
|
$1,132
-
kW-mo/yr
|
- | - | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,561 | $1,416 |
$2,533
111,926
kWh
|
$1,028
-
kW-mo/yr
|
- | - | |
09 | 2.4314: Use synthetic lubricant | $2,247 | $2,020 | - | - |
$2,247
-
MMBtu
|
- | |
10 | 2.2628: Utilize a less expensive cooling method | $1,509 | $1,338 |
$1,074
47,390
kWh
|
$435
-
kW-mo/yr
|
- | - | |
11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $764 | - |
$544
24,052
kWh
|
$220
-
kW-mo/yr
|
- | - | |
12 | 2.4221: Install compressor air intakes in coolest locations | $739 | $295 |
$526
23,226
kWh
|
$213
-
kW-mo/yr
|
- | - | |
13 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $633 | $1,830 |
$524
23,296
kWh
|
$109
-
kW-mo/yr
|
- | - | |
14 | 2.7111: Reduce illumination to minimum necessary levels | $493 | $860 |
$206
9,208
kWh
|
$287
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $55,914 | $121,401 |
$29,661
1,310,581
kWh
|
$25,038
-
kW-mo/yr
|
$2,247
-
MMBtu
|
$(-1,032.0) | ||
TOTAL IMPLEMENTED | $32,493 | $5,818 |
$23,778
1,050,681
kWh
|
$9,747
-
kW-mo/yr
|
- | $(-1,032.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs