| Assessment Year | 2003 |
|---|---|
| Principal Product | Dried Lumber |
| NAICS | 321999: All Other Miscellaneous Wood Product Manufacturing |
| SIC | 2421: Sawmills and Planing Mills, General |
| Sales Range | less than $500 k |
| # of Employees | 8 |
| Plant Area |
10,000
ft2
|
| Annual Production | 4,000
thousand feet
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | West Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $26,362 | 362,631 |
kWh
|
$0.073 |
| Electricity Fees | $1,317 | - |
|
- |
| Natural Gas | $80,174 | 9,993 |
MMBtu
|
$8.02 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $69,131 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,755 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.1331: Burn a less expensive grade of fuel | $52,226 | $153,000 | - | - | - | $52,226 | |
| 02 | 2.2414: Use waste heat from hot flue gases to preheat | $12,150 | $1,695 | - |
$12,150
-
MMBtu
|
- | - | |
| 03 | 2.4151: Develop a repair/replace policy | $1,940 | $240 |
$1,990
26,077
kWh
|
- | $(-50.0) | - | |
| 04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,652 | $1,000 | - |
$1,652
-
MMBtu
|
- | - | |
| 05 | 2.2511: Insulate bare equipment | $1,163 | $38 | - |
$1,163
-
MMBtu
|
- | - | |
| TOTAL RECOMMENDED | $69,131 | $155,973 |
$1,990
26,077
kWh
|
$14,965
-
MMBtu
|
$(-50.0) | $52,226 | ||
| TOTAL IMPLEMENTED | $4,755 | $1,278 |
$1,990
26,077
kWh
|
$2,815
-
MMBtu
|
$(-50.0) | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs