Assessment Year | 2003 |
---|---|
Principal Product | Dried Lumber |
NAICS | 321999: All Other Miscellaneous Wood Product Manufacturing |
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | less than $500 k |
# of Employees | 8 |
Plant Area |
10,000
ft2
|
Annual Production | 4,000
thousand feet
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | West Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $26,362 | 362,631 |
kWh
|
$0.073 |
Electricity Fees | $1,317 | - |
|
- |
Natural Gas | $80,174 | 9,993 |
MMBtu
|
$8.02 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $69,131 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,755 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.1331: Burn a less expensive grade of fuel | $52,226 | $153,000 | - | - | - | $52,226 | |
02 | 2.2414: Use waste heat from hot flue gases to preheat | $12,150 | $1,695 | - |
$12,150
-
MMBtu
|
- | - | |
03 | 2.4151: Develop a repair/replace policy | $1,940 | $240 |
$1,990
26,077
kWh
|
- | $(-50.0) | - | |
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,652 | $1,000 | - |
$1,652
-
MMBtu
|
- | - | |
05 | 2.2511: Insulate bare equipment | $1,163 | $38 | - |
$1,163
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $69,131 | $155,973 |
$1,990
26,077
kWh
|
$14,965
-
MMBtu
|
$(-50.0) | $52,226 | ||
TOTAL IMPLEMENTED | $4,755 | $1,278 |
$1,990
26,077
kWh
|
$2,815
-
MMBtu
|
$(-50.0) | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs