| Assessment Year | 2015 |
|---|---|
| Principal Product | aluminum castings |
| NAICS | 331529: Other Nonferrous Metal Foundries (except Die-Casting) |
| SIC | 3365: Aluminum Foundries |
| Sales Range | $10 M to 50M |
| # of Employees | 10 |
| Plant Area |
30,000
ft2
|
| Annual Production | 60,000
pieces
|
| Production Hrs. Annual | 2,730
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $66,511 | 852,000 |
kWh
|
$0.078 |
| Electricity Demand | $37,380 | 6,660 |
kW-mo/yr
|
$5.61 |
| Natural Gas | $25,304 | 2,550 |
MMBtu
|
$9.92 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,089 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,734 | $6,785 |
$1,522
19,490
kWh
|
$212
-
kW-mo/yr
|
|
| 02 | 2.7135: Install occupancy sensors | $1,023 | $610 |
$750
9,607
kWh
|
$273
-
kW-mo/yr
|
|
| 03 | 2.4322: Use or replace with energy efficient substitutes | $1,332 | $4,400 |
$1,055
13,520
kWh
|
$278
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $4,089 | $11,795 |
$3,327
42,617
kWh
|
$762
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs