Assessment Year | 2002 |
---|---|
Principal Product | Folding cartons |
NAICS |
n/a
|
SIC | 2674: Uncoated Paper and Multiwall Bags |
Sales Range | $50 M to 100M |
# of Employees | 247 |
Plant Area |
200,000
ft2
|
Annual Production | 88,000
ton
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $665,304 | 19,747,000 |
kWh
|
$0.034 |
Electricity Demand | $277,846 | 35,156 |
kW-mo/yr
|
$7.90 |
Natural Gas | $123,883 | 21,812 |
MMBtu
|
$5.68 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $62,850 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $27,353 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $4,772 | $1,000 | - | - |
$4,772
-
MMBtu
|
- | - | - | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,727 | $80 |
$2,760
100,237
kWh
|
$967
-
kW-mo/yr
|
- | - | - | - | - | |
03 | 2.4221: Install compressor air intakes in coolest locations | $1,090 | $296 |
$815
29,593
kWh
|
$275
-
kW-mo/yr
|
- | - | - | - | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $5,600 | - |
$4,188
152,067
kWh
|
$1,412
-
kW-mo/yr
|
- | - | - | - | - | |
05 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $2,412 | $2,100 |
$1,476
53,619
kWh
|
$936
-
kW-mo/yr
|
- | - | - | - | - | |
06 | 2.2511: Insulate bare equipment | $5,402 | $305 | - | - |
$5,402
-
MMBtu
|
- | - | - | - | |
07 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $8,312 | $400 |
$6,577
238,795
kWh
|
$2,215
-
kW-mo/yr
|
- | - | - | $(-480.0) | - | |
08 | 2.7135: Install occupancy sensors | $1,554 | $970 |
$1,162
42,192
kWh
|
$392
-
kW-mo/yr
|
- | - | - | - | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $346 | $2,010 |
$153
5,567
kWh
|
$193
-
kW-mo/yr
|
- | - | - | - | - | |
10 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,136 | $2,744 | - | - |
$1,136
-
MMBtu
|
- | - | - | - | |
11 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $396 | $956 | - | - | - | - |
$396
-
gal
|
- | - | |
12 | 3.4115: Recover and reuse cooling water | $14,103 | $7,000 | - | - | - |
$14,103
-
Tgal
|
- | - | - | |
13 | 4.652: Replace existing equipment with more suitable substitutes | $14,000 | $6,000 | - | - | - | - | - | - | $14,000 | |
TOTAL RECOMMENDED | $62,850 | $23,861 |
$17,131
622,070
kWh
|
$6,390
-
kW-mo/yr
|
$11,310
-
MMBtu
|
$14,103
-
Tgal
|
$396
-
gal
|
$(-480.0) | $14,000 | ||
TOTAL IMPLEMENTED | $27,353 | $5,865 |
$16,316
592,477
kWh
|
$6,115
-
kW-mo/yr
|
$5,402
-
MMBtu
|
- | - | $(-480.0) | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs