Assessment Year | 2002 |
---|---|
Principal Product | Bricks |
NAICS |
n/a
|
SIC | 3251: Brick and Structural Clay Tile |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
131,980
ft2
|
Annual Production | 55,000,000
pieces
|
Production Hrs. Annual | 4,680
hrs
|
Location (State) | Maryland |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $141,887 | 6,138,639 |
kWh
|
$0.023 |
Electricity Demand | $133,732 | 13,448 |
kW-mo/yr
|
$9.94 |
Electricity Fees | $40,413 | - |
|
- |
Natural Gas | $1,441,815 | 219,872 |
MMBtu
|
$6.56 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,967 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,894 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,684 | - |
$2,836
95,518
kWh
|
$1,848
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.2511: Insulate bare equipment | $348 | $151 | - | - |
$348
-
MMBtu
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $945 | - |
$573
19,227
kWh
|
$372
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $414 | $100 |
$251
8,449
kWh
|
$163
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $6,015 | $230 |
$3,976
133,901
kWh
|
$2,591
-
kW-mo/yr
|
- | - | $(-552.0) | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,109 | $138 |
$1,131
50,689
kWh
|
$978
-
kW-mo/yr
|
- | - | - | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $1,052 | $930 |
$635
21,389
kWh
|
$417
-
kW-mo/yr
|
- | - | - | - | |
08 | 2.7134: Use photocell controls | $579 | $300 |
$191
6,446
kWh
|
$388
-
kW-mo/yr
|
- | - | - | - | |
09 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $5,021 | $4,000 | - | - | - |
$5,021
-
lb
|
- | - | |
10 | 4.322: Eliminate old stock and modify inventory control | $3,800 | $690 | - | - | - | - | - | $3,800 | |
11 | 4.652: Replace existing equipment with more suitable substitutes | $5,000 | $845 | - | - | - | - | - | $5,000 | |
TOTAL RECOMMENDED | $29,967 | $7,384 |
$9,593
335,619
kWh
|
$6,757
-
kW-mo/yr
|
$348
-
MMBtu
|
$5,021
-
lb
|
$(-552.0) | $8,800 | ||
TOTAL IMPLEMENTED | $18,894 | $1,609 |
$8,958
314,230
kWh
|
$6,340
-
kW-mo/yr
|
$348
-
MMBtu
|
- | $(-552.0) | $3,800 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs