Assessment Year 2002
Principal Product Bricks
NAICS
n/a
SIC 3251: Brick and Structural Clay Tile
Sales Range $10
M
to 50
M
# of Employees 110
Plant Area 131,980
ft2
Annual Production 55,000,000
pieces
Production Hrs. Annual 4,680
hrs
Location (State) Maryland

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $141,887 6,138,639
kWh
Electricity Demand $133,732 13,448
kW-mo/yr
Electricity Fees $40,413 -
Natural Gas $1,441,815 219,872
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $29,967 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $18,894

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings Personnel Changes Savings Administrative Changes Savings
01 2.4111: Utilize energy-efficient belts and other improved mechanisms $4,684 - $2,836
95,518
kWh
$1,848
-
kW-mo/yr
- - - -
02 2.2511: Insulate bare equipment $348 $151 - - $348
-
MMBtu
- - -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $945 - $573
19,227
kWh
$372
-
kW-mo/yr
- - - -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $414 $100 $251
8,449
kWh
$163
-
kW-mo/yr
- - - -
05 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary $6,015 $230 $3,976
133,901
kWh
$2,591
-
kW-mo/yr
- - $(-552.0) -
06 2.4231: Reduce the pressure of compressed air to the minimum required $2,109 $138 $1,131
50,689
kWh
$978
-
kW-mo/yr
- - - -
07 2.4221: Install compressor air intakes in coolest locations $1,052 $930 $635
21,389
kWh
$417
-
kW-mo/yr
- - - -
08 2.7134: Use photocell controls $579 $300 $191
6,446
kWh
$388
-
kW-mo/yr
- - - -
09 3.6193: Install equipment (eg compactor) to reduce disposal costs $5,021 $4,000 - - - $5,021
-
lb
- -
10 4.322: Eliminate old stock and modify inventory control $3,800 $690 - - - - - $3,800
11 4.652: Replace existing equipment with more suitable substitutes $5,000 $845 - - - - - $5,000
TOTAL RECOMMENDED $29,967 $7,384 $9,593
335,619
kWh
$6,757
-
kW-mo/yr
$348
-
MMBtu
$5,021
-
lb
$(-552.0) $8,800
TOTAL IMPLEMENTED $18,894 $1,609 $8,958
314,230
kWh
$6,340
-
kW-mo/yr
$348
-
MMBtu
- $(-552.0) $3,800
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings Personnel Changes Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs