| Assessment Year | 2001 |
|---|---|
| Principal Product | Commercial China Ware |
| NAICS |
n/a
|
| SIC | 3262: Vitreous China Table and Kitchen Articles |
| Sales Range | $1 M to 5M |
| # of Employees | 63 |
| Plant Area |
80,000
ft2
|
| Annual Production | 1,500,000
pieces
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $134,868 | 1,417,910 |
kWh
|
$0.095 |
| Electricity Demand | $46,430 | 3,610 |
kW-mo/yr
|
$12.86 |
| Natural Gas | $108,727 | 11,261 |
MMBtu
|
$9.66 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $88,356 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $52,709 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,955 | $540 |
$461
12,599
kWh
|
$1,494
-
kW-mo/yr
|
- | - | - | - | |
| 02 | 2.2515: Use optimum thickness insulation | $6,260 | $2,160 | - | - |
$6,260
-
MMBtu
|
- | - | - | |
| 03 | 2.2511: Insulate bare equipment | $1,287 | $145 | - | - |
$1,287
-
MMBtu
|
- | - | - | |
| 04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,007 | $500 | - | - |
$1,007
-
MMBtu
|
- | - | - | |
| 05 | 2.4157: Establish a predictive maintenance program | $1,806 | $480 |
$467
12,892
kWh
|
$1,339
-
kW-mo/yr
|
- | - | - | - | |
| 06 | 2.2414: Use waste heat from hot flue gases to preheat | $9,940 | $1,885 | - | - |
$9,940
-
MMBtu
|
- | - | - | |
| 07 | 2.1224: Replace boiler | $17,262 | $9,690 | - | - |
$17,262
-
MMBtu
|
- | - | - | |
| 08 | 2.2414: Use waste heat from hot flue gases to preheat | $7,438 | $3,538 | - | - |
$7,438
-
MMBtu
|
- | - | - | |
| 09 | 2.1221: Replace obsolete burners with more efficient ones | $4,019 | $5,330 | - | - |
$4,019
-
MMBtu
|
- | - | - | |
| 10 | 3.5316: Contract a wood pallet recycling company | $480 | $100 | - | - | - | - |
$480
-
lb
|
- | |
| 11 | 3.4111: Use closed cycle process to minimize waste water production | $20,054 | $1,307 | - | - | - |
$20,054
-
Tgal
|
- | - | |
| 12 | 4.432: Cross-train personnel to avoid lost time | $16,848 | $750 | - | - | - | - | - | $16,848 | |
| TOTAL RECOMMENDED | $88,356 | $26,425 |
$928
25,491
kWh
|
$2,833
-
kW-mo/yr
|
$47,213
-
MMBtu
|
$20,054
-
Tgal
|
$480
-
lb
|
$16,848 | ||
| TOTAL IMPLEMENTED | $52,709 | $10,812 |
$928
25,491
kWh
|
$2,833
-
kW-mo/yr
|
$11,566
-
MMBtu
|
$20,054
-
Tgal
|
$480
-
lb
|
$16,848 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs