Assessment Year | 1998 |
---|---|
Principal Product | Gas Fireplace Logs |
NAICS |
n/a
|
SIC | 3433: Heating Equipment, Except Electric and Warm Air Furnaces |
Sales Range | $5 M to 10M |
# of Employees | 85 |
Plant Area |
100,000
ft2
|
Annual Production | 0
pieces
|
Production Hrs. Annual | 4,368
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $89,489 | 1,790,152 |
kWh
|
$0.050 |
Natural Gas | $69,019 | 26,037 |
MMBtu
|
$2.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $36,184 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,439 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,375 | $270 |
$1,375
24,033
kWh
|
- | - | - | |
02 | 2.4133: Use most efficient type of electric motors | $8,130 | $3,077 |
$8,130
60,961
kWh
|
- | - | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,920 | $1,920 |
$1,920
38,101
kWh
|
- | - | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $200 | $196 |
$200
4,103
kWh
|
- | - | - | |
05 | 2.7241: Install outside air damper / economizer on hvac unit | $612 | $1,150 |
$612
12,309
kWh
|
- | - | - | |
06 | 2.2514: Cover open tanks | $1,436 | $1,126 | - |
$1,436
-
MMBtu
|
- | - | |
07 | 2.7447: Install vinyl strip / high speed / air curtain doors | $484 | $170 |
$484
53,341
kWh
|
- | - | - | |
08 | 2.2492: Use "heat wheel" or other heat exchanger to cross-exchange building exhaust air with make-up air | $3,620 | $1,660 |
$3,620
434,936
kWh
|
- | - | - | |
09 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $280 | - | - | - | - | $280 | |
10 | 3.4115: Recover and reuse cooling water | $2,877 | $2,800 | - | - |
$2,877
-
Tgal
|
- | |
11 | 4.521: Clear and rent existing space | $12,000 | - | - | - | - | $12,000 | |
12 | 4.511: Expand operations into unused space | $3,250 | - | - | - | - | $3,250 | |
TOTAL RECOMMENDED | $36,184 | $12,369 |
$16,341
627,784
kWh
|
$1,436
-
MMBtu
|
$2,877
-
Tgal
|
$15,530 | ||
TOTAL IMPLEMENTED | $15,439 | $5,437 |
$11,909
176,436
kWh
|
- | - | $3,530 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs