| Assessment Year | 1997 |
|---|---|
| Principal Product | Hydrocarbon Resin |
| NAICS |
n/a
|
| SIC | 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers |
| Sales Range | $100 M to 500M |
| # of Employees | 330 |
| Plant Area |
1,950,000
ft2
|
| Annual Production | 70,000,000
lb
|
| Production Hrs. Annual | 8,568
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,035,910 | 44,621,630 |
kWh
|
$0.023 |
| Electricity Demand | $638,645 | 78,074 |
kW-mo/yr
|
$8.18 |
| Electricity Fees | $77,869 | - |
|
- |
| Natural Gas | $712,382 | 146,775 |
MMBtu
|
$4.85 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $227,209 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $7,853 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Increase in Production Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,254 | $439 |
$126
4,982
kWh
|
$1,128
-
kW-mo/yr
|
- | - | - | - | - | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $220 | $600 |
$220
8,792
kWh
|
- | - | - | - | - | - | |
| 03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $4,312 | $2,000 | - | - |
$4,312
-
MMBtu
|
- | - | - | - | |
| 04 | 2.1213: Direct warmest air to combustion intake | $4,636 | $11,600 | - | - |
$4,636
-
MMBtu
|
- | - | - | - | |
| 05 | 2.2511: Insulate bare equipment | $262 | $268 | - | - |
$262
-
MMBtu
|
- | - | - | - | |
| 06 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $2,025 | - | - | - | - | - | - | $2,025 | - | |
| 07 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $25,500 | $5,000 | - | - | - | $(-19,500.0) | $45,000 | - | - | |
| 08 | 4.652: Replace existing equipment with more suitable substitutes | $189,000 | $2,360 | - | - | - | - | - | - | $189,000 | |
| TOTAL RECOMMENDED | $227,209 | $22,267 |
$346
13,774
kWh
|
$1,128
-
kW-mo/yr
|
$9,210
-
MMBtu
|
$(-19,500.0) | $45,000 | $2,025 | $189,000 | ||
| TOTAL IMPLEMENTED | $7,853 | $2,707 |
$126
4,982
kWh
|
$1,128
-
kW-mo/yr
|
$4,574
-
MMBtu
|
- | - | $2,025 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Increase in Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs