Assessment Year | 1996 |
---|---|
Principal Product | Metal Fabricated Shelving Products |
NAICS |
n/a
|
SIC | 3444: Sheet Metal Work |
Sales Range | $50 M to 100M |
# of Employees | 44 |
Plant Area |
144,000
ft2
|
Annual Production | 14,800,000
lb
|
Production Hrs. Annual | 3,510
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $50,944 | 1,330,598 |
kWh
|
$0.038 |
Electricity Demand | $93,048 | 5,468 |
kW-mo/yr
|
$17.02 |
Electricity Fees | $6,052 | - |
|
- |
Natural Gas | $77,062 | 11,841 |
MMBtu
|
$6.51 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $49,105 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $32,137 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $16,104 | $1,410 |
$4,308
118,699
kWh
|
$11,796
-
kW-mo/yr
|
- | - | - | |
02 | 2.4133: Use most efficient type of electric motors | $2,402 | $1,998 |
$213
5,862
kWh
|
$2,189
-
kW-mo/yr
|
- | - | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $369 | $480 |
$369
9,965
kWh
|
- | - | - | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $386 | $184 |
$386
10,551
kWh
|
- | - | - | - | |
05 | 2.4314: Use synthetic lubricant | $446 | $1,300 |
$446
12,309
kWh
|
- | - | - | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $585 | $14 |
$585
16,120
kWh
|
- | - | - | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $653 | $70 |
$653
17,878
kWh
|
- | - | - | - | |
08 | 2.7241: Install outside air damper / economizer on hvac unit | $842 | $1,347 |
$842
23,154
kWh
|
- | - | - | - | |
09 | 2.1113: Reduce combustion air flow to optimum | $8,365 | $5,000 | - | - |
$8,365
-
MMBtu
|
- | - | |
10 | 2.2511: Insulate bare equipment | $305 | $100 | - | - |
$305
-
MMBtu
|
- | - | |
11 | 3.1191: Change procedures / equipment / operating conditions | $4,168 | $40,000 | - | - | - | - | $4,168 | |
12 | 3.4113: Treat and reuse rinse waters | $3,288 | $2,910 |
$(-383.0)
(-10,551)
kWh
|
- | - |
$4,892
-
Tgal
|
$(-1,221.0) | |
13 | 3.5217: Reuse / recycle/ sell paper products | $11,192 | $150 | - | - | - | - | $11,192 | |
TOTAL RECOMMENDED | $49,105 | $54,963 |
$7,419
203,987
kWh
|
$13,985
-
kW-mo/yr
|
$8,670
-
MMBtu
|
$4,892
-
Tgal
|
$14,139 | ||
TOTAL IMPLEMENTED | $32,137 | $5,606 |
$6,960
191,384
kWh
|
$13,985
-
kW-mo/yr
|
- | - | $11,192 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings |