Assessment Year 1996
Principal Product Valves
NAICS
n/a
SIC 3492: Fluid Power Valves and Hose Fittings
Sales Range $50
M
to 100
M
# of Employees 240
Plant Area 70,545
ft2
Annual Production 7,000,000
pieces
Production Hrs. Annual 4,800
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $160,922 4,452,521
kWh
Electricity Demand $48,022 9,568
kW-mo/yr
Electricity Fees $13,563 -
Natural Gas $9,560 2,806
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $21,509 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $8,594

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Liquid (non-haz) Savings Administrative Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $7,618 $2,400 $5,302
139,215
kWh
$2,316
-
kW-mo/yr
- - -
02 2.4133: Use most efficient type of electric motors $917 $6,390 $293
7,620
kWh
$624
-
kW-mo/yr
- - -
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $406 $1,920 $406
10,551
kWh
- - - -
04 2.4221: Install compressor air intakes in coolest locations $1,328 $748 $1,328
34,877
kWh
- - - -
05 2.4314: Use synthetic lubricant $1,774 $1,600 $1,774
46,600
kWh
- - - -
06 2.7241: Install outside air damper / economizer on hvac unit $569 $1,467 $569
14,947
kWh
- - - -
07 2.2437: Recover waste heat from equipment $303 $523 - - $303
-
MMBtu
- -
08 3.1291: Eliminate practice of mixing waste streams $8,594 $5,400 $(-251.0)
(-6,448)
kWh
- - $9,085
-
gal
$(-240.0)
TOTAL RECOMMENDED $21,509 $20,448 $9,421
247,362
kWh
$2,940
-
kW-mo/yr
$303
-
MMBtu
$9,085
-
gal
$(-240.0)
TOTAL IMPLEMENTED $8,594 $5,400 $(-251.0)
(-6,448)
kWh
- - $9,085
-
gal
$(-240.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Liquid (non-haz) Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs