Assessment Year | 1996 |
---|---|
Principal Product | Valves |
NAICS |
n/a
|
SIC | 3492: Fluid Power Valves and Hose Fittings |
Sales Range | $50 M to 100M |
# of Employees | 240 |
Plant Area |
70,545
ft2
|
Annual Production | 7,000,000
pieces
|
Production Hrs. Annual | 4,800
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $160,922 | 4,452,521 |
kWh
|
$0.036 |
Electricity Demand | $48,022 | 9,568 |
kW-mo/yr
|
$5.02 |
Electricity Fees | $13,563 | - |
|
- |
Natural Gas | $9,560 | 2,806 |
MMBtu
|
$3.41 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,509 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,594 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,618 | $2,400 |
$5,302
139,215
kWh
|
$2,316
-
kW-mo/yr
|
- | - | - | |
02 | 2.4133: Use most efficient type of electric motors | $917 | $6,390 |
$293
7,620
kWh
|
$624
-
kW-mo/yr
|
- | - | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $406 | $1,920 |
$406
10,551
kWh
|
- | - | - | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $1,328 | $748 |
$1,328
34,877
kWh
|
- | - | - | - | |
05 | 2.4314: Use synthetic lubricant | $1,774 | $1,600 |
$1,774
46,600
kWh
|
- | - | - | - | |
06 | 2.7241: Install outside air damper / economizer on hvac unit | $569 | $1,467 |
$569
14,947
kWh
|
- | - | - | - | |
07 | 2.2437: Recover waste heat from equipment | $303 | $523 | - | - |
$303
-
MMBtu
|
- | - | |
08 | 3.1291: Eliminate practice of mixing waste streams | $8,594 | $5,400 |
$(-251.0)
(-6,448)
kWh
|
- | - |
$9,085
-
gal
|
$(-240.0) | |
TOTAL RECOMMENDED | $21,509 | $20,448 |
$9,421
247,362
kWh
|
$2,940
-
kW-mo/yr
|
$303
-
MMBtu
|
$9,085
-
gal
|
$(-240.0) | ||
TOTAL IMPLEMENTED | $8,594 | $5,400 |
$(-251.0)
(-6,448)
kWh
|
- | - |
$9,085
-
gal
|
$(-240.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs