Assessment Year | 1996 |
---|---|
Principal Product | Industrial Pinch Valves |
NAICS |
n/a
|
SIC | 3491: Industrial Valves |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
167,280
ft2
|
Annual Production | 54,000
pieces
|
Production Hrs. Annual | 4,670
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $68,093 | 1,931,125 |
kWh
|
$0.035 |
Electricity Demand | $124,926 | 7,141 |
kW-mo/yr
|
$17.49 |
Electricity Fees | $13,194 | - |
|
- |
Natural Gas | $13,973 | 4,477 |
MMBtu
|
$3.12 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,438 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,365 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,444 | $5,648 |
$4,444
116,061
kWh
|
- | - | |
02 | 2.4133: Use most efficient type of electric motors | $191 | $860 |
$191
4,689
kWh
|
- | - | |
03 | 2.7243: Improve air circulation with destratification fans / other methods | $1,968 | $1,600 |
$(-40.0)
(-879)
kWh
|
$2,008
-
MMBtu
|
- | |
04 | 2.7241: Install outside air damper / economizer on hvac unit | $11,051 | $11,628 |
$11,051
288,687
kWh
|
- | - | |
05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $3,465 | $3,740 | - |
$3,465
-
MMBtu
|
- | |
06 | 2.2443: Re-use or recycle hot or cold process exhaust air | $1,054 | $1,100 | - |
$1,054
-
MMBtu
|
- | |
07 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $265 | $2,000 | - | - |
$265
-
lb
|
|
TOTAL RECOMMENDED | $22,438 | $26,576 |
$15,646
408,558
kWh
|
$6,527
-
MMBtu
|
$265
-
lb
|
||
TOTAL IMPLEMENTED | $8,365 | $12,248 |
$4,635
120,750
kWh
|
$3,465
-
MMBtu
|
$265
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs