Assessment Year | 1995 |
---|---|
Principal Product | Beverage Bottle Labels |
NAICS |
n/a
|
SIC | 2679: Converted Paper and Paperboard Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 90 |
Plant Area |
100,000
ft2
|
Annual Production | 2,000,000,000
pieces
|
Production Hrs. Annual | 6,864
hrs
|
Location (State) | West Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $68,970 | 1,069,461 |
kWh
|
$0.064 |
Natural Gas | $33,142 | 3,478 |
MMBtu
|
$9.53 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $30,389 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,427 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,697 | $662 |
$3,697
80,012
kWh
|
- | - | |
02 | 2.4133: Use most efficient type of electric motors | $3,299 | $5,490 |
$3,299
71,219
kWh
|
- | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,044 | $1,240 |
$1,044
22,567
kWh
|
- | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $271 | $295 |
$271
5,862
kWh
|
- | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $733 | $15 |
$733
15,826
kWh
|
- | - | |
06 | 2.1213: Direct warmest air to combustion intake | $773 | $2,700 | - |
$773
-
MMBtu
|
- | |
07 | 2.2136: Install / repair insulation on steam lines | $791 | $1,071 | - |
$791
-
MMBtu
|
- | |
08 | 2.7241: Install outside air damper / economizer on hvac unit | $8,325 | $3,300 |
$8,325
179,953
kWh
|
- | - | |
09 | 3.3131: Use evaporation to concentrate material | $11,456 | $5,400 | - | - |
$11,456
-
Tgal
|
|
TOTAL RECOMMENDED | $30,389 | $20,173 |
$17,369
375,439
kWh
|
$1,564
-
MMBtu
|
$11,456
-
Tgal
|
||
TOTAL IMPLEMENTED | $17,427 | $12,058 |
$16,636
359,613
kWh
|
$791
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs