| Assessment Year | 1995 |
|---|---|
| Principal Product | Glass tubes for light bulbs and Picture tubes |
| NAICS |
n/a
|
| SIC | 3229: Pressed and Blown Glass and Glassware, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
160,000
ft2
|
| Annual Production | 35,000,000
lb
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $906,771 | 14,525,498 |
kWh
|
$0.062 |
| Natural Gas | $800,551 | 185,920 |
MMBtu
|
$4.31 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $41,221 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $13,667 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Solid Waste (haz) Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,055 | $630 |
$2,055
53,634
kWh
|
- | - | |
| 02 | 2.2437: Recover waste heat from equipment | $14,990 | $3,690 | - |
$14,990
-
MMBtu
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,062 | $500 |
$4,062
106,096
kWh
|
- | - | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $863 | $480 |
$863
22,567
kWh
|
- | - | |
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,577 | $35 |
$4,577
119,578
kWh
|
- | - | |
| 06 | 2.2136: Install / repair insulation on steam lines | $6,143 | $2,745 | - |
$6,143
-
MMBtu
|
- | |
| 07 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $150 | $255 |
$150
3,810
kWh
|
- | - | |
| 08 | 2.4221: Install compressor air intakes in coolest locations | $544 | $180 |
$544
14,068
kWh
|
- | - | |
| 09 | 3.1161: Eliminate/reduce an operation | $7,837 | - | - | - |
$7,837
-
lb
|
|
| TOTAL RECOMMENDED | $41,221 | $8,515 |
$12,251
319,753
kWh
|
$21,133
-
MMBtu
|
$7,837
-
lb
|
||
| TOTAL IMPLEMENTED | $13,667 | $4,535 |
$7,524
196,365
kWh
|
$6,143
-
MMBtu
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Solid Waste (haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs