| Assessment Year | 1995 |
|---|---|
| Principal Product | Laboratory Incubators and Low Temperature Freezers |
| NAICS |
n/a
|
| SIC | 3811: |
| Sales Range | $10 M to 50M |
| # of Employees | 421 |
| Plant Area |
145,440
ft2
|
| Annual Production | 400,000
pieces
|
| Production Hrs. Annual | 4,080
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $208,879 | 4,371,337 |
kWh
|
$0.048 |
| Natural Gas | $119,675 | 16,672 |
MMBtu
|
$7.18 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $38,822 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,606 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,944 | $1,558 |
$1,944
58,030
kWh
|
- | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $655 | $500 |
$655
19,343
kWh
|
- | |
| 03 | 2.2437: Recover waste heat from equipment | $768 | $374 | - |
$768
-
MMBtu
|
|
| 04 | 2.4221: Install compressor air intakes in coolest locations | $589 | $760 |
$589
17,585
kWh
|
- | |
| 05 | 2.7243: Improve air circulation with destratification fans / other methods | $11,042 | $18,000 | - |
$11,042
-
MMBtu
|
|
| 06 | 2.2511: Insulate bare equipment | $21,174 | $3,902 | - |
$21,174
-
MMBtu
|
|
| 07 | 2.1213: Direct warmest air to combustion intake | $2,650 | $3,780 | - |
$2,650
-
MMBtu
|
|
| TOTAL RECOMMENDED | $38,822 | $28,874 |
$3,188
94,958
kWh
|
$35,634
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $6,606 | $6,972 |
$3,188
94,958
kWh
|
$3,418
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs