Assessment Year 1994
Principal Product Bearings
NAICS
n/a
SIC 3562: Ball and Roller Bearings
Sales Range $50
M
to 100
M
# of Employees 280
Plant Area 300,000
ft2
Annual Production 12,000,000
pieces
Production Hrs. Annual 6,720
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $760,731 15,663,248
kWh
Natural Gas $155,105 33,095
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $37,305 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $14,753

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $4,279 $7,375 $4,279
177,022
kWh
-
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,921 - $1,921
79,426
kWh
-
03 2.4221: Install compressor air intakes in coolest locations $2,094 $1,372 $2,094
86,753
kWh
-
04 2.2437: Recover waste heat from equipment $3,973 $440 - $3,973
-
MMBtu
05 2.7243: Improve air circulation with destratification fans / other methods $3,391 $4,400 - $3,391
-
MMBtu
06 2.2414: Use waste heat from hot flue gases to preheat $11,021 $6,660 - $11,021
-
MMBtu
07 2.7124: Make a practice of turning off lights when not needed $340 $200 $340
14,068
kWh
-
08 2.4314: Use synthetic lubricant $2,246 - $2,246
92,907
kWh
-
09 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $8,040 $35,000 $8,040
332,943
kWh
-
TOTAL RECOMMENDED $37,305 $55,447 $18,920
783,119
kWh
$18,385
-
MMBtu
TOTAL IMPLEMENTED $14,753 $43,947 $14,753
610,786
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs