Assessment Year | 1994 |
---|---|
Principal Product | Recycled paper |
NAICS |
n/a
|
SIC | 2631: Paperboard Mills |
Sales Range | $10 M to 50M |
# of Employees | 85 |
Plant Area |
159,000
ft2
|
Annual Production | 72,000
lb
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,685,226 | 43,542,498 |
kWh
|
$0.039 |
Natural Gas | $282,506 | 75,718 |
MMBtu
|
$3.73 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $135,994 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,592 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,370 | $3,491 |
$1,370
46,893
kWh
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $3,081 | $118,620 |
$3,081
105,217
kWh
|
- | |
03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $32,800 | $5,000 | - |
$32,800
-
MMBtu
|
|
04 | 2.1213: Direct warmest air to combustion intake | $81,877 | $4,570 | - |
$81,877
-
MMBtu
|
|
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $7,334 | - |
$7,334
250,586
kWh
|
- | |
06 | 2.4221: Install compressor air intakes in coolest locations | $962 | $150 |
$962
32,825
kWh
|
- | |
07 | 2.7124: Make a practice of turning off lights when not needed | $807 | - |
$807
27,550
kWh
|
- | |
08 | 2.2136: Install / repair insulation on steam lines | $7,763 | $1,001 | - |
$7,763
-
MMBtu
|
|
TOTAL RECOMMENDED | $135,994 | $132,832 |
$13,554
463,071
kWh
|
$122,440
-
MMBtu
|
||
TOTAL IMPLEMENTED | $12,592 | $122,111 |
$12,592
430,246
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs