| Assessment Year | 1994 |
|---|---|
| Principal Product | Lawn and Garden Equipment |
| NAICS |
n/a
|
| SIC | 3524: Lawn and Garden Tractors and Home Lawn and Garden Equipment |
| Sales Range | $50 M to 100M |
| # of Employees | 415 |
| Plant Area |
210,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $476,051 | 9,315,944 |
kWh
|
$0.051 |
| Natural Gas | $56,987 | 11,918 |
MMBtu
|
$4.78 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $14,008 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,956 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $536 | $214 |
$536
22,274
kWh
|
|
| 02 | 2.4133: Use most efficient type of electric motors | $956 | $28,300 |
$956
6,448
kWh
|
|
| 03 | 2.4221: Install compressor air intakes in coolest locations | $2,464 | $1,220 |
$2,464
63,013
kWh
|
|
| 04 | 2.4314: Use synthetic lubricant | $592 | - |
$592
24,619
kWh
|
|
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,076 | - |
$1,076
44,549
kWh
|
|
| 06 | 2.7241: Install outside air damper / economizer on hvac unit | $7,549 | $3,168 |
$7,549
312,427
kWh
|
|
| 07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $835 | $2,000 |
$835
34,584
kWh
|
|
| TOTAL RECOMMENDED | $14,008 | $34,902 |
$14,008
507,914
kWh
|
||
| TOTAL IMPLEMENTED | $3,956 | $29,734 |
$3,956
91,735
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs