ITAC Assessment: WV0027
ITAC logo
ITAC Assessment: WV0027
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1994
Principal Product Glass Bottles
NAICS
n/a
SIC 3221: Glass Containers
Sales Range $10
M
to 50
M
# of Employees 250
Plant Area 450,000
ft2
Annual Production 0
units
Production Hrs. Annual 8,568
hrs
Location (State) West Virginia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $944,597 22,777,550
kWh
Natural Gas $1,734,252 527,898
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $23,499 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,915

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.4221: Install compressor air intakes in coolest locations $12,819 $2,800 $12,819
492,380
kWh
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,430 - $2,430
93,200
kWh
03 2.7142: Utilize higher efficiency lamps and/or ballasts $745 $1,171 $745
28,722
kWh
04 2.4133: Use most efficient type of electric motors $740 $17,110 $740
28,429
kWh
05 2.4314: Use synthetic lubricant $6,765 - $6,765
259,965
kWh
TOTAL RECOMMENDED $23,499 $21,081 $23,499
902,696
kWh
TOTAL IMPLEMENTED $3,915 $18,281 $3,915
150,351
kWh
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs