Assessment Year | 1994 |
---|---|
Principal Product | Glass Bottles |
NAICS |
n/a
|
SIC | 3221: Glass Containers |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
450,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 8,568
hrs
|
Location (State) | West Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $944,597 | 22,777,550 |
kWh
|
$0.041 |
Natural Gas | $1,734,252 | 527,898 |
MMBtu
|
$3.29 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $23,499 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,915 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $12,819 | $2,800 |
$12,819
492,380
kWh
|
|
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,430 | - |
$2,430
93,200
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $745 | $1,171 |
$745
28,722
kWh
|
|
04 | 2.4133: Use most efficient type of electric motors | $740 | $17,110 |
$740
28,429
kWh
|
|
05 | 2.4314: Use synthetic lubricant | $6,765 | - |
$6,765
259,965
kWh
|
|
TOTAL RECOMMENDED | $23,499 | $21,081 |
$23,499
902,696
kWh
|
||
TOTAL IMPLEMENTED | $3,915 | $18,281 |
$3,915
150,351
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs