Assessment Year | 1993 |
---|---|
Principal Product | PVC Products |
NAICS |
n/a
|
SIC | 3081: Unsupported Plastics Film and Sheet |
Sales Range | $50 M to 100M |
# of Employees | 400 |
Plant Area |
500,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $644,627 | 19,634,525 |
kWh
|
$0.033 |
Natural Gas | $529,124 | 148,777 |
MMBtu
|
$3.56 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,765 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,800 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,687 | $1,500 | - |
$1,687
-
MMBtu
|
|
02 | 2.2414: Use waste heat from hot flue gases to preheat | $1,050 | $1,800 | - |
$1,050
-
MMBtu
|
|
03 | 2.4221: Install compressor air intakes in coolest locations | $302 | $170 |
$302
17,292
kWh
|
- | |
04 | 2.7243: Improve air circulation with destratification fans / other methods | $1,915 | $3,200 | - |
$1,915
-
MMBtu
|
|
05 | 2.7124: Make a practice of turning off lights when not needed | $758 | $570 |
$758
43,376
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $53 | $916 |
$53
2,931
kWh
|
- | |
TOTAL RECOMMENDED | $5,765 | $8,156 |
$1,113
63,599
kWh
|
$4,652
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,800 | $3,156 |
$1,113
63,599
kWh
|
$1,687
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs