| Assessment Year | 2024 |
|---|---|
| Principal Product | Additive Manufactured Goods |
| NAICS | 325199: All Other Basic Organic Chemical Manufacturing |
| SIC | 3399: Primary Metal Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 16 |
| Plant Area |
41,000
ft2
|
| Annual Production | 500,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $78,463 | 568,127 |
kWh
|
$0.14 | |
| Electricity Demand | $19,222 | 1,544 |
kW-mo/yr
|
$12.45 | |
| Electricity Fees | $5,980 | - |
|
- | |
| Waste Disposal Costs | |||||
| Water Usage | $9,497 | 9,000 |
Tgal
|
$1.06 | |
| TOTAL YEARLY COSTS | $113,162 | ||||
| RECOMMENDED SAVINGS* | $169,607 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $144,527 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3141: Use battery storage for demand control | $81,464 | $500,000 |
$38,213
307,450
kWh
|
$43,251
-
kW-mo/yr
|
|
| 02 | 2.9114: Use solar heat to make electricty | $63,063 | $212,582 |
$54,413
394,010
kWh
|
$8,650
-
kW-mo/yr
|
|
| 03 | 2.4226: Use / purchase optimum sized compressor | $8,140 | $17,500 |
$6,937
50,232
kWh
|
$1,203
-
kW-mo/yr
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,867 | $7,205 |
$6,986
50,589
kWh
|
$881
-
kW-mo/yr
|
|
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,405 | - |
$3,755
27,188
kWh
|
$650
-
kW-mo/yr
|
|
| 06 | 2.7134: Use photocell controls | $2,875 | $2,520 |
$1,682
12,182
kWh
|
$1,193
-
kW-mo/yr
|
|
| 07 | 2.3132: Recharge batteries on during off-peak demand periods | $1,793 | $100 | - |
$1,793
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $169,607 | $739,907 |
$111,986
841,651
kWh
|
$57,621
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $144,527 | $712,582 |
$92,626
701,460
kWh
|
$51,901
-
kW-mo/yr
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs