Assessment Year | 1997 |
---|---|
Principal Product | Flour based mixes |
NAICS |
n/a
|
SIC | 2041: Flour and Other Grain Mill Products |
Sales Range | $100 M to 500M |
# of Employees | 250 |
Plant Area |
257,710
ft2
|
Annual Production | 156,000,000
lb
|
Production Hrs. Annual | 6,720
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $359,158 | 12,391,559 |
kWh
|
$0.029 |
Electricity Demand | $196,504 | 27,684 |
kW-mo/yr
|
$7.10 |
Electricity Fees | $13,560 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,522,869 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,696 | $75 | n/a |
$1,875
64,771
kWh
|
$821
-
kW-mo/yr
|
- | - |
02 | 2.7111: Reduce illumination to minimum necessary levels | $2,241 | $290 | n/a |
$1,561
53,927
kWh
|
$680
-
kW-mo/yr
|
- | - |
03 | 2.7261: Install timers and/or thermostats | $1,809 | $1,200 | n/a |
$1,809
62,427
kWh
|
- | - | - |
04 | 2.7261: Install timers and/or thermostats | $1,689 | $1,050 | n/a |
$1,689
58,324
kWh
|
- | - | - |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $771 | $341 | n/a |
$516
17,878
kWh
|
$255
-
kW-mo/yr
|
- | - |
06 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $33,414 | - | n/a | - | - |
$33,414
-
lb
|
- |
07 | 3.5313: Increase amount of waste recovered for resale | $11,385 | $360 | n/a | - | - |
$11,385
-
lb
|
- |
08 | 4.112: Replace old machine with new automatic multi-station tool | $2,822,400 | $686,200 | n/a | - | - | - | $2,822,400 |
09 | 4.112: Replace old machine with new automatic multi-station tool | $646,464 | - | n/a | - | - | - | $646,464 |
TOTAL RECOMMENDED | $3,522,869 | $689,516 |
$7,450
257,327
kWh
|
$1,756
-
kW-mo/yr
|
$44,799
-
lb
|
$3,468,864 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs