| Assessment Year | 1993 |
|---|---|
| Principal Product | Personnel Safety Devices |
| NAICS |
n/a
|
| SIC | 3842: Orthopedic, Prosthetic, and Surgical Appliances and Supplies |
| Sales Range | $50 M to 100M |
| # of Employees | 464 |
| Plant Area |
300,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $445,935 | 11,107,269 |
kWh
|
$0.040 |
| Natural Gas | $53,058 | 9,098 |
MMBtu
|
$5.83 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $17,627 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $12,193 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,527 | $1,500 | - |
$1,527
-
MMBtu
|
|
| 02 | 2.4133: Use most efficient type of electric motors | $766 | $35,270 |
$766
35,170
kWh
|
- | |
| 03 | 2.7243: Improve air circulation with destratification fans / other methods | $3,899 | $6,000 | - |
$3,899
-
MMBtu
|
|
| 04 | 2.4221: Install compressor air intakes in coolest locations | $968 | $330 |
$968
44,256
kWh
|
- | |
| 05 | 2.2511: Insulate bare equipment | $54 | $201 |
$54
2,638
kWh
|
- | |
| 06 | 2.2443: Re-use or recycle hot or cold process exhaust air | $8,932 | - | - |
$8,932
-
MMBtu
|
|
| 07 | 2.2414: Use waste heat from hot flue gases to preheat | $1,481 | $1,030 | - |
$1,481
-
MMBtu
|
|
| TOTAL RECOMMENDED | $17,627 | $44,331 |
$1,788
82,064
kWh
|
$15,839
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $12,193 | $37,100 |
$1,734
79,426
kWh
|
$10,459
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs