Assessment Year | 2023 |
---|---|
Principal Product | Testing of Heat Pumps, Water Heaters, Water Treatment |
NAICS | 339999: All Other Miscellaneous Manufacturing |
SIC | 3569: General Industrial Machinery and Equipment, Not Elsewhere |
Sales Range | greater than $500 M |
# of Employees | 65 |
Plant Area |
47,000
ft2
|
Annual Production | 200,000
pieces
|
Production Hrs. Annual | 3,744
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $50,698 | 844,233 |
kWh
|
$0.060 | |
Electricity Demand | $35,849 | 2,361 |
kW-mo/yr
|
$15.18 | |
Electricity Fees | $22,061 | - |
|
- | |
Natural Gas | $48,750 | 5,623 |
MMBtu
|
$8.67 | |
Waste Disposal Costs | |||||
Water Usage | $42,396 | 5,016 |
Tgal
|
$8.45 | |
TOTAL YEARLY COSTS | $199,754 | ||||
RECOMMENDED SAVINGS* | $20,155 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $16,982 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7221: Lower temperature during the winter season and vice-versa | $12,026 | - |
$8,505
141,774
kWh
|
- |
$3,521
-
MMBtu
|
|
02 | 2.6218: Turn off equipment when not in use | $2,584 | - | - | - |
$2,584
-
MMBtu
|
|
03 | 2.4224: Upgrade controls on compressors | $2,381 | $1,240 |
$1,465
24,430
kWh
|
$915
-
kW-mo/yr
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,020 | $1,490 |
$628
10,469
kWh
|
$392
-
kW-mo/yr
|
- | |
05 | 2.2531: Re-size charging openings or add movable cover or door | $546 | $213 | - | - |
$546
-
MMBtu
|
|
06 | 2.1135: Repair furnaces and oven doors so that they seal efficiently | $544 | $240 | - | - |
$544
-
MMBtu
|
|
07 | 2.4221: Install compressor air intakes in coolest locations | $426 | $1,995 |
$262
4,371
kWh
|
$164
-
kW-mo/yr
|
- | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $380 | - |
$209
3,491
kWh
|
$170
-
kW-mo/yr
|
- | |
09 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $138 | $125 |
$138
2,299
kWh
|
- | - | |
10 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $111 | - |
$69
1,146
kWh
|
$43
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $20,155 | $5,303 |
$11,277
187,979
kWh
|
$1,684
-
kW-mo/yr
|
$7,195
-
MMBtu
|
||
TOTAL IMPLEMENTED | $16,982 | $3,698 |
$9,605
160,105
kWh
|
$726
-
kW-mo/yr
|
$6,651
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs