Assessment Year 2023
Principal Product Testing of Heat Pumps, Water Heaters, Water Treatment
NAICS 339999: All Other Miscellaneous Manufacturing
SIC 3569: General Industrial Machinery and Equipment, Not Elsewhere
Sales Range greater than $500
M
# of Employees 65
Plant Area 47,000
ft2
Annual Production 200,000
pieces
Production Hrs. Annual 3,744
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $50,698 844,233
kWh
Electricity Demand $35,849 2,361
kW-mo/yr
Electricity Fees $22,061 -
Natural Gas $48,750 5,623
MMBtu
Waste Disposal Costs
Water Usage $42,396 5,016
Tgal
TOTAL YEARLY COSTS $199,754
RECOMMENDED SAVINGS* $20,155 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $16,982

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.7221: Lower temperature during the winter season and vice-versa $12,026 - $8,505
141,774
kWh
- $3,521
-
MMBtu
02 2.6218: Turn off equipment when not in use $2,584 - - - $2,584
-
MMBtu
03 2.4224: Upgrade controls on compressors $2,381 $1,240 $1,465
24,430
kWh
$915
-
kW-mo/yr
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,020 $1,490 $628
10,469
kWh
$392
-
kW-mo/yr
-
05 2.2531: Re-size charging openings or add movable cover or door $546 $213 - - $546
-
MMBtu
06 2.1135: Repair furnaces and oven doors so that they seal efficiently $544 $240 - - $544
-
MMBtu
07 2.4221: Install compressor air intakes in coolest locations $426 $1,995 $262
4,371
kWh
$164
-
kW-mo/yr
-
08 2.4231: Reduce the pressure of compressed air to the minimum required $380 - $209
3,491
kWh
$170
-
kW-mo/yr
-
09 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available $138 $125 $138
2,299
kWh
- -
10 2.7121: Utilize daylight whenever possible in lieu of artificial light $111 - $69
1,146
kWh
$43
-
kW-mo/yr
-
TOTAL RECOMMENDED $20,155 $5,303 $11,277
187,979
kWh
$1,684
-
kW-mo/yr
$7,195
-
MMBtu
TOTAL IMPLEMENTED $16,982 $3,698 $9,605
160,105
kWh
$726
-
kW-mo/yr
$6,651
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings