Assessment Year 2022
Principal Product Paperboard Packaging
NAICS 323111: Commercial Printing (except Screen and Books)
SIC 2759: Commercial Printing, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 139
Plant Area 275,000
ft2
Annual Production 225,000,000
pieces
Production Hrs. Annual 8,760
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $384,174 6,389,618
kWh
Electricity Demand $266,176 17,530
kW-mo/yr
Electricity Fees $60,560 -
Natural Gas $24,485 5,441
MMBtu
Waste Disposal Costs
Water Usage $8,582 1,520
Tgal
Water Disposal $3,053 571
Tgal
TOTAL YEARLY COSTS $747,030
RECOMMENDED SAVINGS* $69,835 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.7221: Lower temperature during the winter season and vice-versa $26,531 - $15,969
266,148
kWh
$5,360
-
kW-mo/yr
$5,202
-
MMBtu
02 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $17,525 $2,725 $11,658
194,274
kWh
$5,867
-
kW-mo/yr
-
03 2.7224: Reduce space conditioning during non-working hours $13,809 - $7,477
124,615
kWh
- $6,332
-
MMBtu
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $5,314 $3,500 $3,929
65,483
kWh
$1,385
-
kW-mo/yr
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $2,512 $5,221 $2,224
37,066
kWh
$289
-
kW-mo/yr
-
06 2.7243: Improve air circulation with destratification fans / other methods $2,076 $6,500 $(-363.0)
6,050
kWh
- $2,439
-
MMBtu
07 2.4231: Reduce the pressure of compressed air to the minimum required $1,078 - $861
14,343
kWh
$217
-
kW-mo/yr
-
08 2.4221: Install compressor air intakes in coolest locations $990 $1,000 $659
10,975
kWh
$331
-
kW-mo/yr
-
TOTAL RECOMMENDED $69,835 $18,946 $42,414
718,954
kWh
$13,448
-
kW-mo/yr
$13,973
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs