Assessment Year | 2021 |
---|---|
Principal Product | Molded Silicone Medical Devices |
NAICS | 326291: Rubber Product Manufacturing for Mechanical Use |
SIC | 3061: Molded, Extruded, and Lathe-Cut Mechanical Rubber Goods |
Sales Range | $50 M to 100M |
# of Employees | 390 |
Plant Area |
40,000
ft2
|
Annual Production | 400,000,000
pieces
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $588,662 | 12,240,082 |
kWh
|
$0.048 | |
Electricity Demand | $328,526 | 23,980 |
kW-mo/yr
|
$13.70 | |
Electricity Fees | $67,488 | - |
|
- | |
Natural Gas | $27,450 | 5,770 |
MMBtu
|
$4.76 | |
Waste Disposal Costs | |||||
Water Usage | $16,169 | 1,995 |
Tgal
|
$8.10 | |
TOTAL YEARLY COSTS | $1,028,295 | ||||
RECOMMENDED SAVINGS* | $32,468 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.1224: Replace boiler | $14,495 | $38,512 | - | - |
$14,495
-
MMBtu
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,315 | $3,500 |
$4,137
86,186
kWh
|
$1,178
-
kW-mo/yr
|
- | |
03 | 2.7241: Install outside air damper / economizer on hvac unit | $4,757 | $2,560 |
$4,757
99,099
kWh
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,639 | $8,039 |
$2,584
53,828
kWh
|
$1,055
-
kW-mo/yr
|
- | |
05 | 2.7135: Install occupancy sensors | $1,584 | $2,625 |
$1,584
32,995
kWh
|
- | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $1,380 | $2,300 |
$983
20,480
kWh
|
$397
-
kW-mo/yr
|
- | |
07 | 2.4239: Eliminate or reduce compressed air usage | $1,298 | $4,575 |
$1,298
27,030
kWh
|
- | - | |
TOTAL RECOMMENDED | $32,468 | $62,111 |
$15,343
319,618
kWh
|
$2,631
-
kW-mo/yr
|
$14,495
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs