ITAC Assessment: WM0160
ITAC logo
ITAC Assessment: WM0160
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2020
Principal Product Mixed Meat & Bone Meal and Tallow
NAICS 311613: Rendering and Meat Byproduct Processing
SIC 2077: Animal and Marine Fats and Oils
Sales Range $100
M
to 500
M
# of Employees 200
Plant Area 160,000
ft2
Annual Production 95,000
ton
Production Hrs. Annual 8,736
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,041,863 23,232,643
kWh
Electricity Demand $406,359 45,657
kW-mo/yr
Natural Gas $1,846,882 492,502
MMBtu
Waste Disposal Costs
Water Usage $1 80,000
Tgal
Water Disposal $780,847 123,514
Tgal
TOTAL YEARLY COSTS $4,075,952
RECOMMENDED SAVINGS* $178,083 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.2414: Use waste heat from hot flue gases to preheat $142,628 $60,000 - - $142,628
-
MMBtu
02 2.6218: Turn off equipment when not in use $10,840 - $10,840
241,830
kWh
- -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $9,683 $10,855 $9,177
204,667
kWh
$506
-
kW-mo/yr
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $8,267 $3,450 $6,479
144,497
kWh
$1,788
-
kW-mo/yr
-
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $4,847 $11,890 $4,063
90,620
kWh
$784
-
kW-mo/yr
-
06 2.7135: Install occupancy sensors $1,260 $720 $1,194
26,637
kWh
$66
-
kW-mo/yr
-
07 2.4221: Install compressor air intakes in coolest locations $296 $1,631 $232
5,184
kWh
$64
-
kW-mo/yr
-
08 2.2511: Insulate bare equipment $261 $657 - - $261
-
MMBtu
TOTAL RECOMMENDED $178,083 $89,203 $31,986
713,435
kWh
$3,208
-
kW-mo/yr
$142,889
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs