Assessment Year | 2020 |
---|---|
Principal Product | Mixed Meat & Bone Meal and Tallow |
NAICS | 311613: Rendering and Meat Byproduct Processing |
SIC | 2077: Animal and Marine Fats and Oils |
Sales Range | $100 M to 500M |
# of Employees | 200 |
Plant Area |
160,000
ft2
|
Annual Production | 95,000
ton
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $1,041,863 | 23,232,643 |
kWh
|
$0.045 | |
Electricity Demand | $406,359 | 45,657 |
kW-mo/yr
|
$8.90 | |
Natural Gas | $1,846,882 | 492,502 |
MMBtu
|
$3.75 | |
Waste Disposal Costs | |||||
Water Usage | $1 | 80,000 |
Tgal
|
$0.000 | |
Water Disposal | $780,847 | 123,514 |
Tgal
|
$6.32 | |
TOTAL YEARLY COSTS | $4,075,952 | ||||
RECOMMENDED SAVINGS* | $178,083 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $142,628 | $60,000 | - | - |
$142,628
-
MMBtu
|
|
02 | 2.6218: Turn off equipment when not in use | $10,840 | - |
$10,840
241,830
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,683 | $10,855 |
$9,177
204,667
kWh
|
$506
-
kW-mo/yr
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,267 | $3,450 |
$6,479
144,497
kWh
|
$1,788
-
kW-mo/yr
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,847 | $11,890 |
$4,063
90,620
kWh
|
$784
-
kW-mo/yr
|
- | |
06 | 2.7135: Install occupancy sensors | $1,260 | $720 |
$1,194
26,637
kWh
|
$66
-
kW-mo/yr
|
- | |
07 | 2.4221: Install compressor air intakes in coolest locations | $296 | $1,631 |
$232
5,184
kWh
|
$64
-
kW-mo/yr
|
- | |
08 | 2.2511: Insulate bare equipment | $261 | $657 | - | - |
$261
-
MMBtu
|
|
TOTAL RECOMMENDED | $178,083 | $89,203 |
$31,986
713,435
kWh
|
$3,208
-
kW-mo/yr
|
$142,889
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs