Assessment Year | 2019 |
---|---|
Principal Product | Kitchen and Lavatory Faucets |
NAICS | 332913: Plumbing Fixture Fitting and Trim Manufacturing |
SIC | 3432: Plumbing Fixture Fittings and Trim |
Sales Range | $100 M to 500M |
# of Employees | 75 |
Plant Area |
132,308
ft2
|
Annual Production | 4,964,000
lb
|
Production Hrs. Annual | 7,056
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $628,832 | 8,169,929 |
kWh
|
$0.077 | |
Natural Gas | $104,120 | 26,461 |
MMBtu
|
$3.93 | |
Waste Disposal Costs | |||||
Water Usage | $4,308 | 1,213 |
Tgal
|
$3.55 | |
TOTAL YEARLY COSTS | $737,260 | ||||
RECOMMENDED SAVINGS* | $60,166 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $2,002 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1122: Re-size charging openings or add a movable door on equipment | $29,234 | $3,500 |
$29,234
381,546
kWh
|
- | |
02 | 3.1223: Use fog nozzles / spray rinsing instead of immersion rinsing | $10,866 | $8,300 |
$10,866
141,120
kWh
|
- | |
03 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $7,173 | $2,200 |
$7,173
93,151
kWh
|
- | |
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $3,925 | $2,210 | - |
$3,925
-
MMBtu
|
|
05 | 2.6218: Turn off equipment when not in use | $3,800 | $1,040 |
$3,800
49,348
kWh
|
- | |
06 | 2.7444: Close holes and openings in building such as broken windows | $2,032 | $771 | - |
$2,032
-
MMBtu
|
|
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,002 | $3,768 |
$2,002
26,001
kWh
|
- | |
08 | 2.6241: Reduce temperature of process equipment when on standby | $1,134 | - |
$1,134
14,722
kWh
|
- | |
TOTAL RECOMMENDED | $60,166 | $21,789 |
$54,209
705,888
kWh
|
$5,957
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,002 | $3,768 |
$2,002
26,001
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs