| Assessment Year | 2019 |
|---|---|
| Principal Product | Fluid Power Valves and Hose Fittings |
| NAICS | 332912: Fluid Power Valve and Hose Fitting Manufacturing |
| SIC | 3492: Fluid Power Valves and Hose Fittings |
| Sales Range | $100 M to 500M |
| # of Employees | 800 |
| Plant Area |
114,920
ft2
|
| Annual Production | 10,000
units
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $335,562 | 5,915,086 |
kWh
|
$0.057 | |
| Electricity Demand | $86,117 | 13,399 |
kW-mo/yr
|
$6.43 | |
| Electricity Fees | $82,002 | - |
|
- | |
| Natural Gas | $22,333 | 3,166 |
MMBtu
|
$7.06 | |
| Waste Disposal Costs | |||||
| Water Usage | $38,269 | 3,148 |
Tgal
|
$12.16 | |
| TOTAL YEARLY COSTS | $564,283 | ||||
| RECOMMENDED SAVINGS* | $64,173 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $949 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $15,957 | $23,048 |
$15,957
281,269
kWh
|
- | - | - | |
| 02 | 2.9114: Use solar heat to make electricty | $15,707 | $180,540 |
$15,707
276,867
kWh
|
- | - | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,799 | $14,222 |
$8,804
155,199
kWh
|
$1,995
-
kW-mo/yr
|
- | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,331 | $4,500 |
$6,791
119,714
kWh
|
$1,540
-
kW-mo/yr
|
- | - | |
| 05 | 2.7231: Use radiant heater for spot heating | $5,016 | $4,425 | - | - |
$5,016
-
MMBtu
|
- | |
| 06 | 2.4221: Install compressor air intakes in coolest locations | $2,363 | $2,793 |
$1,928
33,980
kWh
|
$435
-
kW-mo/yr
|
- | - | |
| 07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,682 | $2,100 |
$1,371
24,170
kWh
|
$311
-
kW-mo/yr
|
- | - | |
| 08 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,660 | $710 | - | - |
$1,660
-
MMBtu
|
- | |
| 09 | 2.7135: Install occupancy sensors | $949 | $500 |
$949
16,723
kWh
|
- | - | - | |
| 10 | 2.7447: Install vinyl strip / high speed / air curtain doors | $595 | $2,400 | - | - |
$595
-
MMBtu
|
- | |
| 11 | 2.7447: Install vinyl strip / high speed / air curtain doors | $485 | $1,210 | - | - |
$485
-
MMBtu
|
- | |
| 12 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $316 | $480 |
$191
3,364
kWh
|
$30
-
kW-mo/yr
|
- | $96 | |
| 13 | 2.7124: Make a practice of turning off lights when not needed | $313 | - |
$313
5,520
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $64,173 | $236,928 |
$52,011
916,806
kWh
|
$4,310
-
kW-mo/yr
|
$7,756
-
MMBtu
|
$96 | ||
| TOTAL IMPLEMENTED | $949 | $500 |
$949
16,723
kWh
|
- | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs