ITAC Assessment: WM0133
ITAC logo
ITAC Assessment: WM0133
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2019
Principal Product Fluid Power Valves and Hose Fittings
NAICS 332912: Fluid Power Valve and Hose Fitting Manufacturing
SIC 3492: Fluid Power Valves and Hose Fittings
Sales Range $100
M
to 500
M
# of Employees 800
Plant Area 114,920
ft2
Annual Production 10,000
units
Production Hrs. Annual 6,000
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $335,562 5,915,086
kWh
Electricity Demand $86,117 13,399
kW-mo/yr
Electricity Fees $82,002 -
Natural Gas $22,333 3,166
MMBtu
Waste Disposal Costs
Water Usage $38,269 3,148
Tgal
TOTAL YEARLY COSTS $564,283
RECOMMENDED SAVINGS* $64,173 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $949

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $15,957 $23,048 $15,957
281,269
kWh
- - -
02 2.9114: Use solar heat to make electricty $15,707 $180,540 $15,707
276,867
kWh
- - -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $10,799 $14,222 $8,804
155,199
kWh
$1,995
-
kW-mo/yr
- -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $8,331 $4,500 $6,791
119,714
kWh
$1,540
-
kW-mo/yr
- -
05 2.7231: Use radiant heater for spot heating $5,016 $4,425 - - $5,016
-
MMBtu
-
06 2.4221: Install compressor air intakes in coolest locations $2,363 $2,793 $1,928
33,980
kWh
$435
-
kW-mo/yr
- -
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,682 $2,100 $1,371
24,170
kWh
$311
-
kW-mo/yr
- -
08 2.7447: Install vinyl strip / high speed / air curtain doors $1,660 $710 - - $1,660
-
MMBtu
-
09 2.7135: Install occupancy sensors $949 $500 $949
16,723
kWh
- - -
10 2.7447: Install vinyl strip / high speed / air curtain doors $595 $2,400 - - $595
-
MMBtu
-
11 2.7447: Install vinyl strip / high speed / air curtain doors $485 $1,210 - - $485
-
MMBtu
-
12 2.7142: Utilize higher efficiency lamps and/or ballasts $316 $480 $191
3,364
kWh
$30
-
kW-mo/yr
- $96
13 2.7124: Make a practice of turning off lights when not needed $313 - $313
5,520
kWh
- - -
TOTAL RECOMMENDED $64,173 $236,928 $52,011
916,806
kWh
$4,310
-
kW-mo/yr
$7,756
-
MMBtu
$96
TOTAL IMPLEMENTED $949 $500 $949
16,723
kWh
- - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs