Assessment Year | 2019 |
---|---|
Principal Product | Batter breaded frozen fish |
NAICS | 311710: Seafood Product Preparation and Packaging |
SIC | 2092: Prepared Fresh or Frozen Fish and Seafoods |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
31,740
ft2
|
Annual Production | 20,000,000
lb
|
Production Hrs. Annual | 2,400
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $106,036 | 1,377,908 |
kWh
|
$0.077 | |
Electricity Demand | $46,284 | 5,445 |
kW-mo/yr
|
$8.50 | |
Electricity Fees | $(-1,282.0) | - |
|
- | |
Natural Gas | $13,352 | 2,410 |
MMBtu
|
$5.54 | |
Waste Disposal Costs | |||||
Water Usage | $33,563 | 3,680 |
Tgal
|
$9.12 | |
TOTAL YEARLY COSTS | $197,953 | ||||
RECOMMENDED SAVINGS* | $30,638 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $1,647 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $21,662 | $106,000 |
$21,662
270,829
kWh
|
- | - | - | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,306 | $8,640 |
$2,130
27,675
kWh
|
$1,176
-
kW-mo/yr
|
- | - | |
03 | 2.4322: Use or replace with energy efficient substitutes | $2,382 | $12,660 |
$2,067
26,874
kWh
|
$315
-
kW-mo/yr
|
- | - | |
04 | 2.4133: Use most efficient type of electric motors | $992 | $1,240 |
$862
11,202
kWh
|
$130
-
kW-mo/yr
|
- | - | |
05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $743 | $1,010 | - | - |
$743
-
MMBtu
|
- | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $650 | $168 |
$419
5,438
kWh
|
$231
-
kW-mo/yr
|
- | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $561 | - |
$280
3,641
kWh
|
$281
-
kW-mo/yr
|
- | - | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $245 | $300 |
$123
1,601
kWh
|
$122
-
kW-mo/yr
|
- | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $98 | $4,120 |
$64
841
kWh
|
$10
-
kW-mo/yr
|
- | $24 | |
TOTAL RECOMMENDED | $30,638 | $134,138 |
$27,606
348,101
kWh
|
$2,264
-
kW-mo/yr
|
$743
-
MMBtu
|
$24 | ||
TOTAL IMPLEMENTED | $1,647 | $5,430 |
$467
6,083
kWh
|
$412
-
kW-mo/yr
|
$743
-
MMBtu
|
$24 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs