Assessment Year | 2018 |
---|---|
Principal Product | Hydraulic valves |
NAICS | 332912: Fluid Power Valve and Hose Fitting Manufacturing |
SIC | 3492: Fluid Power Valves and Hose Fittings |
Sales Range | $50 M to 100M |
# of Employees | 346 |
Plant Area |
250,000
ft2
|
Annual Production | 7,612,080
pieces
|
Production Hrs. Annual | 4,800
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $792,880 | 12,263,920 |
kWh
|
$0.065 | |
Electricity Demand | $425,327 | 30,821 |
kW-mo/yr
|
$13.80 | |
Electricity Fees | $73,178 | - |
|
- | |
Natural Gas | $99,760 | 23,377 |
MMBtu
|
$4.27 | |
Waste Disposal Costs | |||||
Water Usage | $21,728 | 4,026,711 |
Tgal
|
$0.005 | |
TOTAL YEARLY COSTS | $1,412,873 | ||||
RECOMMENDED SAVINGS* | $142,101 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $33,325 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $61,479 | $72,000 |
$61,479
950,951
kWh
|
- | - | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $33,220 | $39,050 |
$23,284
360,205
kWh
|
$9,936
-
kW-mo/yr
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $31,440 | $42,800 |
$22,029
340,800
kWh
|
$9,411
-
kW-mo/yr
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $6,804 | $2,793 |
$5,024
77,707
kWh
|
$1,780
-
kW-mo/yr
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,936 | $4,135 |
$2,936
45,421
kWh
|
- | - | |
06 | 2.7231: Use radiant heater for spot heating | $2,460 | $3,660 | - | - |
$2,460
-
MMBtu
|
|
07 | 2.7135: Install occupancy sensors | $1,885 | $1,980 |
$1,319
20,429
kWh
|
$566
-
kW-mo/yr
|
- | |
08 | 2.2628: Utilize a less expensive cooling method | $1,390 | $2,469 |
$1,390
21,054
kWh
|
- | - | |
09 | 2.6211: Conserve energy by efficient use of vending machines | $487 | $864 |
$377
5,821
kWh
|
$110
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $142,101 | $169,751 |
$117,838
1,822,388
kWh
|
$21,803
-
kW-mo/yr
|
$2,460
-
MMBtu
|
||
TOTAL IMPLEMENTED | $33,325 | $44,780 |
$23,348
361,229
kWh
|
$9,977
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs