| Assessment Year | 2017 |
|---|---|
| Principal Product | HVAC Eqiupment |
| NAICS | 332322: Sheet Metal Work Manufacturing |
| SIC | 3564: Industrial and Commercial Fans and Blowers and Air Purification Equipment |
| Sales Range | $50 M to 100M |
| # of Employees | 100 |
| Plant Area |
220,000
ft2
|
| Annual Production | 1,137,498
units
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Wisconsin |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $90,459 | 1,750,367 |
kWh
|
$0.052 | |
| Electricity Demand | $59,390 | 4,335 |
kW-mo/yr
|
$13.70 | |
| Electricity Fees | $4,893 | - |
|
- | |
| Natural Gas | $48,734 | 9,665 |
MMBtu
|
$5.04 | |
| Waste Disposal Costs | |||||
| Water Usage | $14,200 | 3,352 |
Tgal
|
$4.24 | |
| Water Disposal | $10,040 | 3,352 |
Tgal
|
$3.00 | |
| TOTAL YEARLY COSTS | $227,716 | ||||
| RECOMMENDED SAVINGS* | $42,456 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $13,294 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $14,609 | $72,000 |
$14,609
282,681
kWh
|
- | - | - | - | |
| 02 | 2.7134: Use photocell controls | $3,191 | $10,230 |
$3,191
61,752
kWh
|
- | - | - | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,895 | $14,722 |
$3,048
58,972
kWh
|
$4,847
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.2414: Use waste heat from hot flue gases to preheat | $7,112 | $14,000 | - | - |
$7,112
-
MMBtu
|
- | - | |
| 05 | 3.4153: Use counter current rinsing to reduce waste water | $3,017 | $3,000 | - | - | - |
$3,017
-
Tgal
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,729 | $1,833 |
$908
17,564
kWh
|
$659
-
kW-mo/yr
|
- | - | $162 | |
| 07 | 2.2113: Repair or replace steam traps | $1,678 | $3,960 | - | - |
$1,678
-
MMBtu
|
- | - | |
| 08 | 2.1221: Replace obsolete burners with more efficient ones | $1,597 | $3,400 | - | - |
$1,597
-
MMBtu
|
- | - | |
| 09 | 2.4221: Install compressor air intakes in coolest locations | $1,233 | $3,124 |
$475
9,212
kWh
|
$758
-
kW-mo/yr
|
- | - | - | |
| 10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $395 | $720 |
$195
3,767
kWh
|
$71
-
kW-mo/yr
|
- | - | $129 | |
| TOTAL RECOMMENDED | $42,456 | $126,989 |
$22,426
433,948
kWh
|
$6,335
-
kW-mo/yr
|
$10,387
-
MMBtu
|
$3,017
-
Tgal
|
$291 | ||
| TOTAL IMPLEMENTED | $13,294 | $24,635 |
$4,150
80,303
kWh
|
$5,577
-
kW-mo/yr
|
$3,275
-
MMBtu
|
- | $291 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs