Assessment Year 2017
Principal Product Frac sand
NAICS 212322: Industrial Sand Mining
SIC 1446: Industrial Sand
Sales Range $50
M
to 100
M
# of Employees 68
Plant Area 5,500,000
ft2
Annual Production 1,300,000
units
Production Hrs. Annual 8,400
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $708,794 11,511,080
kWh
Electricity Demand $237,904 23,147
kW-mo/yr
Electricity Fees $17,275 -
Natural Gas $592,009 156,892
MMBtu
LPG $41,228 2,212
MMBtu
TOTAL YEARLY COSTS $1,597,210
RECOMMENDED SAVINGS* $93,994 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings LPG Savings
01 2.4314: Use synthetic lubricant $29,687 $58,519 $24,003
387,140
kWh
$5,684
-
kW-mo/yr
- -
02 2.7231: Use radiant heater for spot heating $19,679 $3,000 - - - $19,679
-
MMBtu
03 2.7313: Recycle air for heating, ventilation and air conditioning $14,992 $10,774 - - - $14,992
-
MMBtu
04 2.3212: Optimize plant power factor $13,178 $18,800 - $13,178
-
kW-mo/yr
- -
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $6,210 $3,000 $5,021
80,981
kWh
$1,189
-
kW-mo/yr
- -
06 2.7231: Use radiant heater for spot heating $4,749 $2,780 - - $4,749
-
MMBtu
-
07 2.7444: Close holes and openings in building such as broken windows $3,298 $28,500 - - $3,298
-
MMBtu
-
08 2.7124: Make a practice of turning off lights when not needed $980 - $662
10,672
kWh
$318
-
kW-mo/yr
- -
09 2.7135: Install occupancy sensors $865 $345 $700
11,290
kWh
$165
-
kW-mo/yr
- -
10 2.7124: Make a practice of turning off lights when not needed $356 - $214
3,456
kWh
$142
-
kW-mo/yr
- -
TOTAL RECOMMENDED $93,994 $125,718 $30,600
493,539
kWh
$20,676
-
kW-mo/yr
$8,047
-
MMBtu
$34,671
-
MMBtu
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings LPG Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs