| Assessment Year | 2017 |
|---|---|
| Principal Product | Frac sand |
| NAICS | 212322: Industrial Sand Mining |
| SIC | 1446: Industrial Sand |
| Sales Range | $50 M to 100M |
| # of Employees | 68 |
| Plant Area |
5,500,000
ft2
|
| Annual Production | 1,300,000
units
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Wisconsin |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $708,794 | 11,511,080 |
kWh
|
$0.062 |
| Electricity Demand | $237,904 | 23,147 |
kW-mo/yr
|
$10.28 |
| Electricity Fees | $17,275 | - |
|
- |
| Natural Gas | $592,009 | 156,892 |
MMBtu
|
$3.77 |
| LPG | $41,228 | 2,212 |
MMBtu
|
$18.63 |
| TOTAL YEARLY COSTS | $1,597,210 | |||
| RECOMMENDED SAVINGS* | $93,994 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4314: Use synthetic lubricant | $29,687 | $58,519 |
$24,003
387,140
kWh
|
$5,684
-
kW-mo/yr
|
- | - | |
| 02 | 2.7231: Use radiant heater for spot heating | $19,679 | $3,000 | - | - | - |
$19,679
-
MMBtu
|
|
| 03 | 2.7313: Recycle air for heating, ventilation and air conditioning | $14,992 | $10,774 | - | - | - |
$14,992
-
MMBtu
|
|
| 04 | 2.3212: Optimize plant power factor | $13,178 | $18,800 | - |
$13,178
-
kW-mo/yr
|
- | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $6,210 | $3,000 |
$5,021
80,981
kWh
|
$1,189
-
kW-mo/yr
|
- | - | |
| 06 | 2.7231: Use radiant heater for spot heating | $4,749 | $2,780 | - | - |
$4,749
-
MMBtu
|
- | |
| 07 | 2.7444: Close holes and openings in building such as broken windows | $3,298 | $28,500 | - | - |
$3,298
-
MMBtu
|
- | |
| 08 | 2.7124: Make a practice of turning off lights when not needed | $980 | - |
$662
10,672
kWh
|
$318
-
kW-mo/yr
|
- | - | |
| 09 | 2.7135: Install occupancy sensors | $865 | $345 |
$700
11,290
kWh
|
$165
-
kW-mo/yr
|
- | - | |
| 10 | 2.7124: Make a practice of turning off lights when not needed | $356 | - |
$214
3,456
kWh
|
$142
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $93,994 | $125,718 |
$30,600
493,539
kWh
|
$20,676
-
kW-mo/yr
|
$8,047
-
MMBtu
|
$34,671
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs